A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Tibiofibular Space Widening Assessment With a Ball-Tipped Probe in a Syndesmosis Injury Model. | LitMetric

Assessment of syndesmotic instability is not precise with existing evaluation methods. This study was conducted to investigate the use of a ball-tipped probe under arthroscopy for quantitative assessment of tibiofibular space widening in a syndesmosis injury model. The test specimens were 5 uninjured ankles from Thiel-fixed cadavers of 2 male subjects and 3 female subjects of mean age of 82.4 years at death. The ball-tipped probe consisted of a metal probe having a ball at each end with diameters ranging from of 1.5 mm to 5.0 mm, in increments of 0.5 mm. The tibiofibular joint was observed arthroscopically as the largest-diameter ball probe as possible was inserted into its anterior third, middle, or posterior third portion with the ankle in natural plantarflexion or under external rotational stress. These measurements were performed for the uninjured ankle and then performed following Bassett's ligament sectioning, anterior inferior tibiofibular ligament sectioning, interosseous membrane distal 15 cm sectioning, or deltoid ligament, and posterior inferior tibiofibular ligament sectioning, with the sections added in this sequence and each followed by a similar assessment. The results of quantitative assessment of tibiofibular space widening with the ball-tipped probe in the syndesmosis injury model under arthroscopy were that the maximum possible diameter of ball probe that could be inserted was 1.5 to 2.0 mm in the uninjured state, 3.0 to 3.5 mm in the sectioned anterior inferior tibiofibular ligament model, and 5.0 mm in the severe-state model. The ball probe can serve as an effective tool for quantitative assessment of the intraoperative instability in cases of syndesmosis injury.

Download full-text PDF

Source
http://dx.doi.org/10.1053/j.jfas.2020.03.024DOI Listing

Publication Analysis

Top Keywords

ball-tipped probe
16
syndesmosis injury
16
tibiofibular space
12
space widening
12
injury model
12
quantitative assessment
12
ball probe
12
ligament sectioning
12
inferior tibiofibular
12
tibiofibular ligament
12

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!