Background: First-pass efficacy (FPE) is an established marker of technical and clinical efficacy among mechanical thrombectomy (MT) techniques. It is unclear what the optimal approach is in achieving FPE. We present a single-center experience comparing rates of FPE among 2 MT techniques and evaluate the potential predictors of FPE among other outcomes.
Methods: A single-center retrospective analysis was carried out of patients with consecutive large-vessel occlusion strokes (LVOS) of anterior circulation from September 2015 to April 2019 who underwent MT and for whom data were available on the status of FPE. Four MT techniques were identified: ADAPT (a direct first-pass aspiration), SrADAPT (stent retriever with aspiration), SRBG (stent retriever with balloon guide catheter), and STRAP (stent retriever-aspiration and proximal flow arrest). The primary outcome was FPE and secondary outcomes included the rate of successful reperfusion.
Results: Among 226 patients with LVOS of the anterior circulation who underwent MT, data were available for 164 on FPE for the 4 MT techniques. SRBG was the most prevalent technique. No significant difference was found in rates of FPE among the 4 MT techniques (P = 0.332). No independent predictors of FPE were identified on multivariable analysis. STRAP had the highest rate of successful reperfusion compared with the other techniques (P = 0.049) and was the only independent predictor of that outcome (P = 0.027).
Conclusions: Among patients with LVOS of the anterior circulation, the rate of FPE did not differ among the 4 MT techniques. There were no predictors of FPE among the studied variables. STRAP was the only predictor of successful reperfusion.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.wneu.2020.08.209 | DOI Listing |
Clin Neuroradiol
December 2024
Neurointerventional Department CDI, Hospital Clinic de Barcelona, Barcelona, Spain.
Introduction: Although stentrievers (SRs) are widely used for mechanical thrombectomy (MT), the impact of device dimensions on optimizing reperfusion outcomes in high clot burden cases is unclear. Our study aimed to investigate the effect of SR size on angiographic and clinical outcomes in patients with acute terminal internal cerebral artery (TICA) occlusion.
Methods: We analyzed ROSSETTI registry data to compare technical and clinical outcomes of TICA occlusion patients treated with MT without rescue therapy, according to SR diameter and length: 6 × 41-50 mm, 6 × 20-40 mm, and <6 × 20-50 mm.
Various sensor applications have been developed for protection against hazardous environments, and research on functional materials to enhance performance has also been pursued. The M13 bacteriophage (M13) has found utility in sensor applications like disease diagnosis and detection of harmful substances due to its potential for controlling interaction with target substances through adjustments in electrochemical and mechanical properties via genetic engineering technology. However, while optimizing reactivity or binding affinity between M13 and target materials is crucial for sensor performance enhancement, precise dynamic measurement methods for this were lacking.
View Article and Find Full Text PDFPLoS One
November 2024
Department of Basic Health Sciences, College of Applied Medical Sciences, Qassim University, Buraydah, Saudi Arabia.
Tamarix articulate from the Tamaricaece family is a halophytic plant. This plant is commonly called Athal or Tamarix in different Arabic and Asian countries. Due to the high load of polyphenolic phytochemicals, the plant has been used as a therapeutic option against several diseases for decades.
View Article and Find Full Text PDFMicromachines (Basel)
October 2024
School of Electrical and Information Engineering, Tianjin University, Tianjin 300072, China.
Classical frequency-stabilized lasers have achieved high-frequency stability and reproducibility; however, their extensive wavelength spacing limits their utility in various scenarios. This study introduces a novel frequency-stabilized laser scheme that integrates a Fabry-Perot etalon (FPE) with digital control technology and wavelength modulation techniques. The FPE, characterized by multiple transmission peaks at minimal frequency intervals, provides stable frequency references for different lasers, thereby enhancing the system's flexibility and adaptability.
View Article and Find Full Text PDFInterv Neuroradiol
October 2024
John A. Burns School of Medicine, University of Hawai'i at Mānoa, Honolulu, HI, USA.
Introduction: With emerging evidence supporting the clinical efficacy and safety of mechanical thrombectomy (MT) for distal medium vessel occlusions (DMVOs), MT devices specifically designed to navigate through smaller caliber and more delicate tortuous distal cerebrovasculature are required. This study describes our single-center experience using the AXS Vecta 46 intermediate catheter for first-line thromboaspiration of DMVOs.
Methods: We identified all patients who underwent MT using the Vecta 46 for first-line thromboaspiration for primary or secondary DMVOs.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!