Purpose: To report 5-year results of the prospective, multicenter study designed to evaluate the Zenith Fenestrated AAA Endovascular Graft (William A. Cook Australia, Brisbane, Australia) for juxtarenal abdominal aortic aneurysms (AAAs).

Methods: Sixty-seven patients (54 male, mean age 74 ± 8 years) were prospectively enrolled at 14 U.S. centers from 2005 to 2012. Fenestrated stent grafts were used in patients with infrarenal aortic neck lengths of 4 to 14 mm to target 178 renal-mesenteric arteries with a mean of 2.7 vessels per patient. At 5 years, 42 of the 67 patients completed the final study follow-up, with clinical examination obtained in 41 and computed tomography imaging in 39. Outcomes adjudicated by a clinical events committee included all-cause and aneurysm-related mortality, major adverse events, renal stent occlusion/stenosis, renal function changes and renal infarcts, aneurysm sac enlargement (>5 mm), device migration (≥10 mm), type I/III endoleak, and secondary interventions.

Results: Median follow-up was 59.8 months (range, 0.1-67.5 months). There were seven deaths, including one (1.5%) within 30 days (procedure-related) and six beyond 30 days (not procedure-related in five, indeterminate in one). At 5 years, freedom from all-cause mortality was 88.8 ± 4.2% and freedom from aneurysm-related mortality was 96.8 ± 2.3%. There were no aneurysm ruptures or conversions to open surgery. Of the 129 renal arteries targeted by fenestrations, five (4%) occluded and 14 (11%) developed in-stent stenosis. Treatment included redo stenting/angioplasty in 13 vessels, renal artery bypass in 2 vessels, and failed thrombectomy in 1 vessel. Primary and secondary renal target patency was 82.7 ± 4.1% and 95.7 ± 2.1% at 5 years, respectively. Dialysis was required in one patient who had pre-existing chronic kidney disease. During the 5 years, there was 1 type IA endoleak (1.5%), 1 type IB endoleak (1.5%), 2 device migrations (3%), and 4 aneurysm sac enlargements (6%). Overall, 81% of patients had sac shrinkage at 5 years. Of 20 patients who underwent secondary interventions, 12 were for renal in-stent stenosis or occlusion, 7 were for endoleak, and 1 was for both indications. Freedom from secondary intervention was 63.5 ± 7.2% at 5 years.

Conclusions: These 5-year results confirm the safety and effectiveness of the Zenith Fenestrated AAA stent graft with no late graft- or aneurysm-related deaths. In-stent stenosis of bare metal renal stents was the most frequent indication for secondary intervention. The low rate of type IA endoleak, sac enlargement, and device migration support its use in patients with juxtarenal AAAs.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jvs.2020.08.128DOI Listing

Publication Analysis

Top Keywords

zenith fenestrated
12
in-stent stenosis
12
type endoleak
12
prospective multicenter
8
multicenter study
8
juxtarenal abdominal
8
abdominal aortic
8
aortic aneurysms
8
fenestrated aaa
8
5 years patients
8

Similar Publications

Stent-graft implantation is a widely recognized method for endovascular treatment of aortic aneurysms. In cases where the aneurysm involves the thoracic and abdominal aorta, repair including fenestrated and branched stent grafts provides a viable alternative. This approach, initially reserved for patients unsuitable for open surgery, has become preferred for anatomically appropriate thoracoabdominal aortic aneurysms.

View Article and Find Full Text PDF
Article Synopsis
  • - The study investigates the effectiveness and safety of using the "electrified wire" technique for creating fenestrations in various types of aortic stent-grafts to treat complex aortic aneurysms.
  • - Results showed that the Zenith and RelayPro stent-grafts performed significantly better than the Endurant in terms of puncture success and fenestration size post-ballooning.
  • - While some damage such as fraying and tearing occurred across all groups, the Endurant group required additional treatment for stenosis, unlike the RelayPro and Zenith groups which showed no significant issues post-procedure.
View Article and Find Full Text PDF

Ten years of physician-modified endografts.

J Vasc Surg

January 2025

Department of Surgery, Division of Vascular and Endovascular Surgery, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA. Electronic address:

Objectives: Physician-modified endografts (PMEGs) have expanded the scope of endovascular abdominal aortic repair beyond the infrarenal aorta. Patients with prohibitively high surgical risk and visceral segment disease are often candidates for this intervention, which mitigates much of the morbidity and mortality associated with conventional open repair. Here we present the institutional PMEG experience of a high-volume aortic center.

View Article and Find Full Text PDF

Background: Endovascular repair of thoracic aortic aneurysms (TAA) in elective settings has demonstrated successful clinical outcomes. However, life-threatening conditions such as rupture are more often managed with open surgical repair due to the high complexity of arch endovascular repair, lack of available off-the-shelf devices, and limited long-term data.

Case Summary: A 49-year-old female with a recent history of prior ascending aortic repair for Type A aortic dissection presented with chest pain and dyspnea.

View Article and Find Full Text PDF

Background: Chronic kidney disease (CKD) has been identified as an independent predictor of poorer long-term prognosis after endovascular aneurysm repair (EVAR) for complex abdominal aortic aneurysm (AAA). However, its impact on short-term perioperative outcomes is conflicting, which can be important for preoperative risk stratification. This study aimed to evaluate the 30-day outcomes of patients with CKD following non-ruptured complex EVAR in a national registry.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!