A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Is there any predictive bone parameter for implant stability in 2-dimensional and 3-dimensional radiologic images? | LitMetric

Is there any predictive bone parameter for implant stability in 2-dimensional and 3-dimensional radiologic images?

Oral Surg Oral Med Oral Pathol Oral Radiol

Professor, Department of Dentomaxillofacial Radiology, Faculty of Dentistry, Beykent University, Istanbul.

Published: March 2021

Objectives: This ex vivo study aimed to compare radiomorphometric parameters between 2-dimensional (2-D) and 3-dimensional (3-D) radiographs and evaluate the influence of preoperative radiologic bone parameters on the clinical outcomes of implant stability.

Study Design: Implant recipient sites in fresh bovine blocks were evaluated on panoramic radiographs for gray value (GV), fractal dimension (FD), number of connected trabeculae (Co), and density of connected trabeculae (CoD). Cone beam computed tomography (CBCT) scans were evaluated for trabecular thickness (TbTh), cortical thickness (CTh), degree of anisotropy (DA), FD, and Co. Insertion torque (IT) and implant stability quotient (ISQ) were measured.

Results: GV was significantly correlated with all parameters in 2-D and 3-D images except FD in 2-D and Co in 3-D, and with all surgical parameters (P ≤ .029). Co and CoD values on panoramic radiographs had significant correlation with TbTh, CTh, and DA values on CBCT images (P < .001). All 2-D parameters and TbTh and CTh in the CBCT data were significantly correlated with IT only (P ≤ .047). Only GV was correlated with ISQ measurements (P ≤ .029).

Conclusions: GV, Co, and CoD values on panoramic radiographs reflect the architecture of trabecular bone and the thickness of cortical bone, and might help predict implant stability in clinical situations.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.oooo.2020.08.009DOI Listing

Publication Analysis

Top Keywords

implant stability
12
panoramic radiographs
12
connected trabeculae
8
2-d 3-d
8
cod values
8
values panoramic
8
tbth cth
8
implant
5
parameters
5
predictive bone
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!