Background: Cardiac implantable electronic device-detected atrial high-rate episodes (AHREs) have been reported to be associated with thromboembolic risks. The present study aimed to investigate the association of echocardiographic and clinical parameters with the occurrence of AHREs in patients with a dual-chamber pacemaker (PMI).
Methods: One hundred forty-seven patients (76 males, 75.2 ± 8.9 years) who did not show atrial tachyarrhythmia before the implantation of the PMI were studied. Diastolic wall strain (DWS) and other measurements were assessed during sinus rhythm using transthoracic echocardiography before the PMI. DWS was calculated from the M-mode echocardiographic measurement of the left ventricular (LV) posterior wall thickness at end-systole (PWs) and end-diastole (PWd), and DWS was defined as (PWs-PWd) / PWs.
Results: AHREs (defined as AHREs duration >6 min and atrial rate >180 bpm) were detected in 50 / 147 patients during follow up (38.3 ± 13.8 months). Patients in the AHREs group had reduced DWS (0.29 ± 0.07 vs. 0.39 ± 0.06, p < 0.0001), larger left atrial volume index, thicker LV posterior diameter, higher rate of patients taking β-blocker / diuretics, and higher prevalence of sinus node dysfunction. On multivariable analysis, only DWS was independently associated with AHREs. Patients with reduced DWS (<0.33) had a higher risk of incidences of AHREs.
Conclusion: LV stiffness assessed by DWS was associated with AHREs in patients with a PMI.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jjcc.2020.08.002 | DOI Listing |
J Physiol
January 2025
Center for Developmental Health, Oregon Health & Science University, Portland, OR, USA.
Robust preclinical models of asymmetric ventricular loading in late gestation reflecting conditions such as hypoplastic left heart syndrome are lacking. We characterized the morphometry and microvascular function of the hypoplastic left ventricle (LV) and remaining right ventricle (RV) in a sham-controlled late gestation fetal lamb model of impaired left ventricular inflow (ILVI). Singleton fetuses were instrumented at ∼120 days gestational age (dGA; term is ∼147 days) with vascular catheters, an aortic flow probe and a deflated left atrial balloon.
View Article and Find Full Text PDFEur Stroke J
January 2025
Neurology and Stroke Unit, ASST Grande Ospedale Metropolitano Niguarda, Milan, Italy.
Background: Severe left ventricular (LV) systolic dysfunction (ejection fraction [EF] < 30%) is a known cardiovascular risk factor and a major cause of cardioembolism. However, less severe forms of LV disease (LVD), such as mild-to-moderate LV dysfunction and LV wall motion abnormalities (LVWMAs), are considered potential minor cardiac sources in Embolic Stroke of Undetermined Source (ESUS), but their role is underexplored. This study aims to evaluate the prevalence of LVD in ESUS and its association with adverse vascular events and mortality.
View Article and Find Full Text PDFObjective: ADHD is one of the most common neurodevelopmental disorders, seen in children and adolescents, and is often treated with various pharmacological agents, especially methylphenidate. There are differing opinions in the literature regarding the cardiovascular safety of long-term methylphenidate use. Studies suggest that the drug may increase the risk of hypertension, myocardial infarction, ventricular arrhythmia, sudden cardiac death, cardiomyopathy, heart failure (HF), pulmonary hypertension, and stroke.
View Article and Find Full Text PDFJ Cardiothorac Surg
January 2025
Department of Cardiovascular Surgery, West China Hospital of Sichuan University, 37# Guoxue Xiang, Chengdu, 610041, Sichuan, China.
Background: Pseudoaneurysm after coarctation of the aorta (CoA) repair is a rare but severe complication. Contributing factors may include infection, hypertension, aortic wall weakness, and turbulent blood flow at the repair site.
Case Presentation: A 35-year-old male presented with recurrent episodes of epistaxis and dizziness was admitted to the emergency department.
Crit Care
January 2025
División de Terapia Intensiva, Hospital Juan A. Fernández, Buenos Aires, Argentina.
The advancements in cardiovascular imaging over the past two decades have been significant. The miniaturization of ultrasound devices has greatly contributed to their widespread adoption in operating rooms and intensive care units. The integration of AI-enabled tools has further transformed the field by simplifying echocardiographic evaluations and enhancing the reproducibility of hemodynamic measurements, even for less experienced operators.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!