Objectives: The aim of this study is to propose and evaluate a new method of volumetric perfusion computed tomography (PCT) incorporated into pancreatic multiphasic contrast enhanced (CE)-CT in the clinical setting.
Methods: In this ethically approved study, PCT was incorporated into our existing scanning protocol in 17 patients and effective doses related to PCT were evaluated. CT values and signal-to-noise ratio (SNR) of anatomical structure were compared in diagnostic images that were acquired using 320-detector volumetric scan mode and 64-detector helical scan mode. In addition, focal lesion depiction was qualitatively assessed in the two groups. Perfusion parameters in normal pancreas were measured by two radiologists and the interobserver-reliability was assessed.
Results: The effective dose of PCT was 5.1 ± 0.3 mSv. The actual effective dose (AED) including the dose used in volumetric scans for diagnostic imaging was 22.8 ± 5.3 mSv and the putative effective dose (PED) was 21.9 ± 9.1 mSv on average. There was no significant difference between AED and PED (p = 0.404). Compared with conventional helical scans, volumetric scans did not decrease CT values or SNR, but rather significantly increased those of the aorta in the arterial phase. Both groups had acceptable qualitatively assessed image quality with no significant difference in the depiction of each structure. There was almost perfect interobserver agreement in the measurement of perfusion parameters (mean ICCs > 0.9).
Conclusions: Our scanning protocol for pancreatic perfusion CT provides high-quality images while requiring lower radiation doses than conventional methods.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.pan.2020.08.010 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!