Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Purpose: To evaluate the optimal period of replanning to spare the rectal dose by investigating daily rectal movements during computed tomography (CT) image-guided proton therapy for prostate cancer.
Materials And Methods: To evaluate the optimum reference period for replanning, we analyzed 1483 sets of daily CT (dCT) images acquired from 40 prostate cancer patients and measured the daily rectal movement along the anterior-posterior direction based on the simulator CT (sCT) images and dCT images. We calculated daily dose distributions based on initial plans on the sCT images and replans on the dCT images for 13 representative patients, and evaluated daily dose volume histograms (DVHs) for the prostate, seminal vesicles, and rectum.
Results: The rectal anterior side on the dCT images around the seminal vesicles largely deviated toward the anterior side relative to the position on the reference sCT images, but the deviation decreased by referring to the dCT images and became nearly zero when we referred to the dCT images after 10-day treatment. The daily DVH values for the prostate showed good dose coverage. For six patients showing rectal movement toward the anterior side, the daily rectal DVH (V ) showed a 3.0 ± 1.7 cc excess from the initial plan and this excess was correlated with 9.9 ± 6.8 mm rectal movement. To identify the patients (37.5% in total) for whom the replanning on the 10th-day and 20th-day CT images reduced the V excess to 0.4 ± 1.5 cc and -0.2 ± 1.3 cc, respectively, we evaluated the accumulated mean doses with a 1.2 cc criterion.
Conclusion: Our data demonstrate that the daily movement of the rectal anterior side tends to move toward the anterior side, which results in a rectal overdose, and the mean of the movement gradually decreases with the passage of days. In such cases, replanning with the reference CT after 10 days is effective to spare the rectal dose.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7592984 | PMC |
http://dx.doi.org/10.1002/acm2.13015 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!