Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Study Design: Test-retest study.
Objective: To describe the test-retest reliability of an individualized approach for peak oxygen uptake (VOpeak) testing in a clinical context, accommodating inpatients with heterogeneous levels of physical functioning.
Setting: Inpatient rehabilitation.
Method: Test-retest on two types of devices (recumbent stepper and arm-crank ergometer) with two predefined protocols of varying load increments on each device. No participants performed all four test modalities. VOpeak, respiratory exchange ratio (RER), peak workload, and the reason for termination were reported. Of 23 participants included, 21 completed the test-retest procedure. Participants were inpatients, ≥18 years, who sustained a spinal cord injury (SCI) within the last 12 months at the time of admission. The median age was 52 years and 74% were male. Median time since injury at the time of the first test (T1) was 5.5 months. Seventeen were classified as American Spinal Injury Association Impairment Scale D. Intraclass correlation coefficients (ICC) and Bland-Altman plots for VOpeak was calculated to determine intra- and intertester reliability of VOpeak.
Results: Mean VOpeak obtained at T1 was 1.91 L/min (95%CI: 1.31-2.51); 1.26 L/min and 2.69 L/min for the recumbent stepper protocols; 0.61 L/min and 1.39 L/min for the arm-crank ergometer protocols. ICC for intra- and intertester reliability was 0.997 (95%CI: 0.986-0.999) and 0.994 (95%CI: 0.978-0.998) respectively. Bland-Altman plots showed a mean difference of -0.005 (SD 0,12) for overall test-retest.
Conclusion: Test-retest reliability was high. Mean VOpeak at discharge from rehabilitation was higher than previously reported and individualized test modalities seemed to yield more optimal results in a heterogenous and representative sample during rehabilitation.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1038/s41393-020-00540-1 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!