Parkinson's disease (PD) is a common neurological disease caused by nerve cells degradation which leads to extremely low level of dopamine (DA) in patients. Therefore, ultrasensitive DA detection is particularly important for the assessment and treatment of Parkinson's patients. In this research, photoelectrochemical (PEC) sensors based on Ag(SR) nanoclusters (AgNCs) with 5-mercapto-2-nitrobenzoic acid (MNBA) ligands were first developed for ultrasensitive and selective detection of DA. Then, hybrid nanomaterials by introducing graphene oxide (GO) and silver nanoparticles (AgNPs) into AgNCs were used to enhance sensing properties. AgNCs/AgNPs/GO based PEC sensors achieved high sensitivity (7.476 nA/μM) and low limit of detection (LOD, S/N = 3, 53 nM) in the linear range 0.16-6 μM DA concentration. Besides DA, PD causes the concentration change of other analytes, such as glutathione (GSH). Multichannel detections of different analytes can provide more information in studying PD. Therefore, carbon dots (CDs) based PEC sensors were designed and achieved high sensing performances on GSH detection. Then, AgNCs/AgNPs/GO and CDs based PEC sensors were combined and extended into light-addressable sensors for multichannel detections of DA and GSH. Algorithms were used to solve interference problems to improve the measurement accuracy of DA and GSH in complex solution. Finally, PD biological model samples from mice were measured by light-addressable sensors. The relationships between the DA and GSH concentration and the PD stage were proved. Our designed light-addressable sensors exhibited advantages of multichannel detection, high sensitivity, fast response and so on. In the future, it can be expanded to detect more biological molecules to provide more information on studying PD.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.talanta.2020.121290 | DOI Listing |
Mikrochim Acta
December 2024
School of Life and Environmental Sciences, School of Intellectual Property, Guilin University of Electronic Technology, Guilin, Guangxi, 541004, People's Republic of China.
A novel carbon-based light-addressable potentiometric aptasensor (C-LAPS) was constructed for detection low-density lipoprotein (LDL) in serum. Carboxylated TiC MXene @reduced graphene oxide (C-MXene@rGO) was used as interface and o-phenylenediamine functionalized nitrogen-doped graphene quantum dots (OPD@NGQDs) as the photoelectric conversion element. The photosensitive layers composed of OPD@NGQDs/C-MXene@rGO exhibit superior photoelectric conversion efficiency and excellent biocompatibility, which contribute to an improved response signal.
View Article and Find Full Text PDFAnal Chem
December 2024
Department of Biophysics, School of Basic Medical Sciences, Health Science Center, Xi'an Jiaotong University, Xi'an 710061, China.
Bioelectrochemistry
April 2025
School of Life and Environmental Sciences, Guilin University of Electronic Technology, Guilin, Guangxi 541004, PR China. Electronic address:
Glypican-3 (GPC3) is exclusively overexpressed in most Hepatocellular carcinoma (HCC) tissue but not in normal liver tissue, making it a promising biomarker for the precise detection of HCC. In this paper, a label-free light-addressable potentiometric sensor (LAPS) decorated by platinumpalladium-hemin-reduced graphene oxide nanocomposites (PtPd@H-rGO NCs) was constructed for determination of GPC3. The GPC3 aptamer (GPC3) and PtPd@H-rGO NCs were modified on the surface of silicon-based LAPS chip to build sensitive unit of LAPS system.
View Article and Find Full Text PDFBiosens Bioelectron
January 2025
Biosensor National Special Laboratory, Key Laboratory for Biomedical Engineering of Ministry of Education, Department of Biomedical Engineering, Zhejiang University, Hangzhou, 310027, China; Binjiang Institute of Zhejiang University, Hangzhou, 310053, China. Electronic address:
Disruption and dysregulation of cellular calcium channel function can lead to diseases such as ischemic stroke, heart failure, and arrhythmias. Corresponding calcium channel drugs typically require preliminary efficacy evaluations using in vitro models such as cells and simulated tissues before clinical testing. However, traditional detection and evaluation methods often encounter challenges in long-term continuous monitoring and lack calcium specificity.
View Article and Find Full Text PDFSensors (Basel)
August 2024
Department of Electronic Engineering, Tohoku University, Sendai 980-8579, Japan.
A light-addressable potentiometric sensor (LAPS) is a semiconductor-based sensor platform for sensing and imaging of various chemical species. Being a potentiometric sensor, no faradaic current flows through its sensing surface, and no electrochemical reaction takes place in the course of LAPS measurement. In this study, a four-electrode system is proposed, in which a LAPS is combined with the conventional three-electrode electrochemical system.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!