Aim: The aim of this study was to assess possible impacts of multiple magnetic resonance imaging (MRI) scans on the function of InterStim™ sacral neurostimulator systems (SNS; Medtronic Inc.) devices and on patient's safety.
Methods: Over the course of 17 years, a total of 16 patients required 72 MRI examinations in various parts of the body. Each time an MRI was performed, the implanting urologist evaluated the SNS device function and deactivated the implant before the scan. Patients were monitored continuously during and after the procedure. After the MRI session, the site of the implanted device was examined, and the SNS device was reactivated.
Results: None of the patients experienced pain or discomfort during or after the MRI scan. Impedances and stimulation amplitudes were recorded before and after MRI and showed no statistically significant changes regarding implant function. Micturition-time charts after MRI procedures were compared with previous records and showed no deviations either. No negative consequences of multiple MRIs have been observed.
Conclusion: This is the first report of patients successfully undergoing multiple MRI scans despite a previously implanted SNS. Sixteen patients underwent more than one MRI scan, with no negative effect on the functional outcome of SNS or negative side effects for the patients.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1002/nau.24496 | DOI Listing |
Am Fam Physician
January 2025
University of Florida College of Medicine, Gainesville.
Jaundice is an indication of hyperbilirubinemia and is caused by derangements in bilirubin metabolism. It is typically apparent when serum bilirubin levels exceed 3 mg/dL and can indicate serious underlying disease of the liver or biliary tract. A comprehensive medical history, review of systems, and physical examination are essential for differentiating potential causes such as alcoholic liver disease, biliary strictures, choledocholithiasis, drug-induced liver injury, hemolysis, or hepatitis.
View Article and Find Full Text PDFJ Neurosurg
January 2025
19Division of Medical Statistics, Division of Data Science, Foundation for Biomedical Research and Innovation at Kobe; and.
Objective: Studies have demonstrated the effectiveness of hydrogel-coated coils (HGCs) to achieve the composite endpoint of decreased recanalization rates and greater safety. Herein, the authors aimed to assess the true ability of second-generation HGCs to prevent recanalization.
Methods: This randomized controlled study, the HYBRID (Hydrocoil Versus Bare Platinum Coil in Recanalization Imaging Data) trial, comparing HGCs with bare platinum coils (BPCs), was conducted in 43 Japanese institutions.
Neurol Neuroimmunol Neuroinflamm
March 2025
Macquarie Medical School, Faculty of Medicine, Health and Human Sciences, Macquarie University, Sydney.
Background And Objectives: Despite the absence of acute lesion activity in multiple sclerosis (MS), chronic neurodegeneration continues to progress, and a potential underlying mechanism could be the kynurenine pathway (KP). Prolonged activation of the KP from chronic inflammation is known to exacerbate the progression of neurodegenerative diseases through the production of neurotoxic metabolites. Among the 8 KP metabolites, six of them, namely kynurenine (KYN), 3-hydroxylkynurenine (3HK), anthranilic acid (AA), kynurenic acid (KYNA), and quinolinic acid (QUIN), have been associated with neurodegeneration.
View Article and Find Full Text PDFPLoS One
January 2025
Department of Electrical Engineering, Shiraz Branch, Islamic Azad University, Shiraz, Iran.
CNN is considered an efficient tool in brain image segmentation. However, neonatal brain images require specific methods due to their nature and structural differences from adult brain images. Hence, it is necessary to determine the optimal structure and parameters for these models to achieve the desired results.
View Article and Find Full Text PDFMagnetic resonance imaging (MRI) is one of the most commonly used tools in neuroscience. However, it implies exposure to high noise levels. Exposure to noise can lead to temporary or permanent hearing loss, especially when the exposure is long and/or repeated.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!