Impact of charge collection efficiency and electronic noise on the performance of solid-state 3D microdetectors.

Phys Med Biol

Departamento de Física de Partículas, Universidade de Santiago de Compostela, 15782-Santiago de Compostela, Spain.

Published: September 2020

Microdosimetry has been traditionally performed through gaseous proportional counters, although in recent years different solid-state microdosimeters have been proposed and constructed for this task. In this paper, we analyze the response of solid-state devices of micrometric size with no intrinsic gain developed by CNM-CSIC (Spain). There are two major aspects of the operation of these devices that affect the reconstruction of the probability distributions and momenta of stochastic quantities related to microdosimetry. For micrometric volumes, the drift and diffusion of the charge carriers gives rise to a partial charge collection efficiency in the peripheral region of the depleted volume. This effect produces a perturbation of the reconstructed pulse height (i.e. imparted energy) distributions with respect to the actual microdosimetric distributions. The relevance of this deviation depends on the size, geometry and operating conditions of the device. On the other hand, the electronic noise from the single-event readout set-up poses a limit on the minimum detectable lineal energy when the microdosimeter size is reduced. This article addresses these issues to provide a framework on the physical constraints for the design and operation of solid-state microdosimeters.

Download full-text PDF

Source
http://dx.doi.org/10.1088/1361-6560/ab87faDOI Listing

Publication Analysis

Top Keywords

charge collection
8
collection efficiency
8
electronic noise
8
solid-state microdosimeters
8
impact charge
4
efficiency electronic
4
noise performance
4
solid-state
4
performance solid-state
4
solid-state microdetectors
4

Similar Publications

Background: Meniscal surgery is one of the most frequent orthopaedic procedures performed worldwide. There is a wide range of possible treatment errors that can occur following meniscal surgery. In Norway, patients subject to treatment errors by hospitals and private institutions can file a compensation claim free of charge to the Norwegian System of Patient Injury Compensation (NPE).

View Article and Find Full Text PDF

Background: Recently, a total of 74 circulating vaccine-derived poliovirus (cVDPV) outbreaks were detected in 39 countries, with 672 confirmed Acute Flaccid Paralysis (AFP) cases identified in 27 countries. Despite progress, Niger experienced cVDPV outbreaks in 2018, highlighting the importance of maintaining AFP surveillance as a tool for polio eradication. This analysis aims to comprehensively assess AFP surveillance trends, patterns, and challenges in Niger, offering insights for public health initiatives in conflict-affected contexts.

View Article and Find Full Text PDF

Modification of silica interfaces by covalent attachment of functional ligands is a primary means of controlling the interfacial chemistry of porous silicas used in separations, environmental cleanup, and biosensing. Recently, modification of hydrophobic, -alkyl-silane-functionalized interfaces has been achieved through self-assembly of zwitterionic phospholipids or mixed-charged surfactants to form "hybrid bilayers", producing interfaces that mimic lipid-bilayer partitioning and provide shape-selective partitioning of aromatic hydrocarbons. Charged headgroups, however, introduce electrostatic interactions that strongly influence the retention of ionizable solutes and require careful control over pH and ionic strength in the solution phase.

View Article and Find Full Text PDF

Background: SB17 is being developed as a biosimilar to ustekinumab reference product (RP), a human monoclonal antibody (IgG1 kappa immunoglobulin) that binds to the common p40 subunit of cytokines interleukin (IL)-23 and IL-12. Binding to this subunit prevents interaction with their receptor, resulting in modulation in the immune system responses that play a key role in inflammatory disease.

Objective: The objective of this study was to demonstrate structural, physicochemical, and biological similarity between ustekinumab RP and SB17 using various state-of-the-art analytical methods.

View Article and Find Full Text PDF

Machine vision model for drip leakage detection of pipeline.

PLoS One

January 2025

School of Power and Mechanical Engineering, Wuhan University, Wuhan, China.

The prevailing trend in industrial equipment development is integration, with pipelines as the lifeline connecting system components. Given the often harsh conditions of these industrial equipment pipelines, leakage is a common occurrence that can disrupt normal operations and, in severe cases, lead to safety accidents. Early detection of even minor drips at the onset of leakage can enable timely maintenance measures, preventing more significant leaks and halting the escalation of pipeline failures.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!