Background: Commonly, the application of radiological and clinical criteria and the determination of galactomannan (GM) in respiratory samples are used as a diagnostic tool for the detection of invasive pulmonary aspergillosis (IPA).

Materials/methods: In this study, two lateral flow assays, OLM Aspergillus lateral flow device (LFD) and IMMY sōna Aspergillus Galactomannan lateral flow assay (LFA), were evaluated at two tertiary hospitals in Germany. A total of 200 bronchoalveolar lavage (BAL) samples from patients with suspicion of IPA were analysed retrospectively. LFD and LFA were evaluated against four different criteria: Blot, EORTC/MSG, Schauwvlieghe and extended Blot criteria and additionally against GM.

Results: The evaluation of four algorithms for the diagnosis of IPA showed that there exist good diagnostic tools to rule out an IPA even before results of Aspergillus culture are available. Sensitivities and negative predictive values are generally higher for the LFA than for the LFD in all four criteria. Specificity and positive predictive values varied depending on the classification criteria. The total agreement between the GM and the LFA cube reader (cut-off = 1) was 84%. The correlation between the GM and LFA was calculated with r = 0.8.

Conclusion: The here presented data indicate that a negative LFA result in BAL fluid can reliable rule out an IPA in a heterogeneous group of ICU patients based on the original Blot criteria. LFA seems to be a promising immunochromatographic test exhibiting a good agreement with positive GM values.

Download full-text PDF

Source
http://dx.doi.org/10.1111/myc.13176DOI Listing

Publication Analysis

Top Keywords

lateral flow
16
flow assays
8
detection invasive
8
invasive pulmonary
8
pulmonary aspergillosis
8
lfa evaluated
8
blot criteria
8
rule ipa
8
predictive values
8
lfa
7

Similar Publications

Quantitative determination of leptin hormone using gold nanoparticle-based lateral flow assay.

Mikrochim Acta

January 2025

Science and Technology Research and Application Center (BITAM), Necmettin Erbakan University, Konya, Türkiye.

A lateral flow assay (LFA) has been developed that can be used in point-of-care (PoC) use for the sensitive determination of leptin hormone. The limit of detection value was 0.158 ng/mL and the limit of quantification value was 0.

View Article and Find Full Text PDF

Background: Adrenaline and glucose are essential biomarkers in human body for maintaining metabolic balance. Abnormal levels of adrenaline and glucose are associated with various diseases. Therefore, it is important to design portable, on-site devices for rapid adrenaline and glucose analysis to safeguard health.

View Article and Find Full Text PDF

Lateral flow immunoassay (LFIA) has the advantages of simplicity and rapidness, and is widely used for the rapid detection of pesticides and other analytes. However, small molecule compounds such as pesticides are often analyzed using competitive LFIA (CLFIA), whose sensitivity often does not meet the actual needs. In this study, a noncompetitive LFIA (NLFIA) for deltamethrin (DM) with high sensitivity was developed by using anti-immunocomplex peptides (AIcPs).

View Article and Find Full Text PDF

Coupling tree-ring and geomorphic analyses to reconstruct the 1950s massive Glacier Lake Outburst Flood at Grosse Glacier, Chilean Patagonia.

Sci Total Environ

January 2025

Climate Change Impacts and Risks in the Anthropocene (C-CIA), Institute for Environmental Sciences, University of Geneva, Geneva, Switzerland; dendrolab.ch, Department of Earth Sciences, University of Geneva, Geneva, Switzerland; Department F.-A. Forel for Environmental and Aquatic Sciences, University of Geneva, Switzerland.

Over recent decades, global warming has led to sustained glacier mass reduction and the formation of glacier lakes dammed by potentially unstable moraines. When such dams break, devastating Glacial Lake Outburst Floods (GLOFs) can occur in high mountain environments with catastrophic effects on populations and infrastructure. To understand the occurrence of GLOFs in space and time, build frequency-magnitude relationships for disaster risk reduction or identify regional links between GLOF frequency and climate warming, comprehensive databases are critically needed.

View Article and Find Full Text PDF

The rapid, sensitive, and accurate detection of paralytic shellfish toxins (PSTs), such as saxitoxin (STX), is critical for protecting human health due to the frequent occurrence of toxic red tides. In this work, to address the low affinity of traditional mouse monoclonal antibodies (m-mAbs), rabbit monoclonal antibodies (r-mAbs) against STX were produced by a single B-cell sorting culture and a cross-selection strategy. The r-mAbs showed 100-fold improvement in sensitivity (IC = 0.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!