A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Response rate and safety in patients with hepatocellular carcinoma treated with transarterial chemoembolization using 40-µm doxorubicin-eluting microspheres. | LitMetric

Purpose: To evaluate the response rate and safety of superselective drug-eluting beats transarterial chemoembolization (DEB-TACE) with doxorubicin-loaded 40-µm microspheres in patients with hepatocellular carcinoma (HCC).

Methods: One hundred and forty-one treatments with doxorubicin-loaded 40-µm microspheres in 83 patients between 2012 and 2017 were retrospectively evaluated. Images of the treated lesions were analyzed before and after each treatment according to mRECIST (modified Response Evaluation Criteria in Solid Tumors). Therapy response (complete response [CR] + partial response [PR]) and disease control (CR + PR + stable disease [SD]) rates were determined, and the correlation between the longitudinal axis (longest diameter of the tumor) and volume was investigated using a newly developed software for systematic tumor response assessment. Additional endpoints were progression-free survival (PFS) and time to progression (TTP).

Results: In the target tumors, a therapy response rate of 63.1% and a disease control rate of 95.7% were achieved. There was a good correlation between the measurement of the longitudinal axis and volume of the measured lesion (r value, 0.954). The median PFS was 2.23 months, and the median TTP was 5.91 months. The serious adverse event rate (SAE) was 10.64%.

Conclusion: Superselective DEB-TACE with 40-µm sized Embozene Tandem™ can be considered an effective and safe treatment, given the number of procedure-related complications.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7810642PMC
http://dx.doi.org/10.1007/s00432-020-03370-zDOI Listing

Publication Analysis

Top Keywords

response rate
12
response
8
rate safety
8
patients hepatocellular
8
hepatocellular carcinoma
8
transarterial chemoembolization
8
doxorubicin-loaded 40-µm
8
40-µm microspheres
8
microspheres patients
8
tumors therapy
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!