Emphasizing the Diagnostic Value of Digital Tomosynthesis in Detecting Hip Fractures.

Tomography

McMaster University Medical Centre; and Department of Diagnostic Imaging, Juravinski Cancer Center, Hamilton Health Sciences, Hamilton, ON.

Published: September 2020

Our institution recently implemented the use of digital tomosynthesis (DTS) to workup emergency room patients with suspected hip fractures after initial negative or indeterminate radiographs. Our purpose is to evaluate the diagnostic accuracy of DTS for hip fracture detection. We performed a retrospective review of all DTS studies over a 17-month period (July 2017 to November 2018). The results of the radiographs and DTS were recorded as either positive or negative for fracture based on the radiology report. Our reference standard for a fracture was either confirmation on subsequent CT or MRI from the same visit or documentation of clinical findings supportive of a fracture in the patient's electronic medical record. For patients with negative DTS who did not undergo subsequent cross-sectional imaging, a missed fracture was excluded if they did not return within 30 days with a confirmed fracture. Among 91 patients, there were 34 confirmed fractures-sites including, 7 femoral necks, 10 pubic rami, and 7 greater trochanters. DTS was positive for fracture in 29 patients; 28 of these fractures were true positives, 6 confirmed on cross-sectional imaging, and 22 confirmed clinically. One false positive was observed in a patient with no clinical evidence of a fracture. Six fractures were not detected by tomosynthesis but confirmed on CT/MRI. The sensitivity and specificity of DTS are 82% and 98%, respectively, compared to that of radiographs alone at 47% and 96%, respectively. DTS is a promising adjunct to radiographs for hip fracture detection in an emergency department.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7442093PMC
http://dx.doi.org/10.18383/j.tom.2020.00031DOI Listing

Publication Analysis

Top Keywords

fracture
9
digital tomosynthesis
8
hip fractures
8
dts
8
hip fracture
8
fracture detection
8
cross-sectional imaging
8
fracture patients
8
confirmed
5
emphasizing diagnostic
4

Similar Publications

Background: Despite extensive studies of the Mesozoic-Cenozoic magmatic history of Svalbard, little has been done on the Paleozoic magmatism due to fewer available outcrops.

Methods: 2D seismic reflection data were used to study magmatic intrusions in the subsurface of eastern Svalbard.

Results: This work presents seismic evidence for west-dipping, Middle Devonian-Mississippian sills in eastern Spitsbergen, Svalbard.

View Article and Find Full Text PDF

Therapeutic effect of titanium locking plate combined with suture anchor repair in proximal humeral fractures.

Pak J Med Sci

January 2025

Zhenfeng Huang Department of Orthopedic Trauma, Wuhan Fourth Hospital, Wuhan, Hubei Province 430000, P.R. China.

Objective: To explore the therapeutic effect of titanium locking plate combined with suture anchor (SA) repair in the treatment of proximal humeral fractures (PHF).

Methods: This retrospective study was conducted by analyzing the clinical data of 113 patients with PHF admitted to Wuhan Fourth Hospital from March 2021 to October 2023. Among them, 55 patients underwent open reduction and internal fixation (OR/IF) using titanium locking plate (OR/IF group), and 58 patients underwent surgery with titanium locking plate combined with SA (SA group).

View Article and Find Full Text PDF

Objective: To evaluate the efficacy of supra-inguinal fascia iliaca compartment block (S-FICB) in patients undergoing proximal femoral nail antirotation (PFNA) internal fixation surgery for intertrochanteric fracture (ITF).

Methods: Retrospective analysis of 95 patients with ITF undergoing PFNA internal fixation surgery in the First People's Hospital of Yong Kang from March 2021 to August 2023 was performed. Among them, 49 patients received general anesthesia (GA; GA group) and 46 patients received S-FICB combined with general anesthesia (S-FICB group).

View Article and Find Full Text PDF

Background: Gravid females with pelvic fractures are rarely encountered by the orthopaedic trauma surgeon. The initial injury can be detrimental to the pregnant patient, but an unnecessary "second hit" from surgery could also contribute to the outcome of the fetus. Understanding the surgical risks for this unique patient population requires knowledge about the negative effects of anesthesia, surgical exposures, and radiation.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!