Background: Cardiovascular magnetic resonance (CMR) image acquisition techniques during exercise typically requires either transient cessation of exercise or complex post-processing, potentially compromising clinical utility. We evaluated the feasibility and reproducibility of a navigated image acquisition method for ventricular volumes assessment during continuous physical exercise.

Methods: Ten healthy volunteers underwent supine cycle ergometer (Lode) exercise CMR on two separate occasions using a free-breathing, multi-shot, navigated, balanced steady-state free precession cine pulse sequence. Images were acquired at 3-stages, baseline and during steady-state exercise at 55% and 75% maximal heart rate (HR), based on a prior supine cardiopulmonary exercise test. Intra-and inter-observer variability and inter-scan reproducibility were derived. Clinical feasibility was tested in a separate cohort of patients with severe mitral regurgitation (n=6).

Results: End-diastolic volume (EDV) of both LV and RV decreased during exercise at 55% and 75% HR, although a reduction in RVEDV index was only observed at 75% HR. Ejection fractions (EF) for both ventricles were significantly higher at 75% HR compared to their respective baselines (LVEF 68%±3% 58%±5%, P=0.001; RVEF 66%±4% 58%±7%, P=0.02). Intra-observer and inter-observer reproducibility of LV parameters was excellent at all 3-stages. Although measurements of RVESV were more variable during exercise, the reproducibility of both RVEF and RV cardiac index was excellent (CV <10%). Inter-scan LV and RV ejection fraction were highly reproducible at all 3 stages, although inter-scan reproducibility of indexed RVESV was only moderate. The protocol was well tolerated by all patients.

Conclusions: Exercise CMR using a free-breathing, multi-shot, navigated cine imaging method allows simultaneous assessment of left and right ventricular volumes during exercise. Intra- and inter-observer reproducibility were excellent. Inter-scan LV and RV ejection fraction were also highly reproducible.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7417762PMC
http://dx.doi.org/10.21037/qims-20-117DOI Listing

Publication Analysis

Top Keywords

image acquisition
12
feasibility reproducibility
8
cardiovascular magnetic
8
magnetic resonance
8
free-breathing multi-shot
8
multi-shot navigated
8
navigated image
8
exercise
8
exercise 55%
8
55% 75%
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!