Vertical jump performance is a commonly used test to measure lower-limb muscle power that is carried out with several types of equipment. The aim of this study was to validate an open-source jump mat (Chronojump Boscosystems) against a proprietary jump mat (Globus Ergo Tester). Sixty-three active sportsmen (age 23.3 ± 2.4 years) completed 8 maximal-effort countermovement jumps (CMJ). The heights of the 504 CMJ were measured from the two jump mats simultaneously. Reliability was examined with intra-class correlation coefficients (ICC), paired samples t-tests, coefficient of variation (CV) and Cronbach's α. Bivariate Pearson's correlation coefficient () was used to examine validity. Effects were evaluated using non-clinical magnitude-based inference. There was almost perfect agreement between instruments (ICC = 0.999-1.000, most likely positive 100/0/0). Paired -test showed a mean difference of 0.03 ± 0.21 cm (90% CI -0.04 - -0.01) between instruments (most likely trivial 0/100/0). Both instruments showed very good stability (α = 1.00, CV = 4.28±1.95%). The smallest worthwhile change and typical error values were 1.3 and 0.29 cm, respectively and therefore, the signal-to-noise ratio of both instruments was large: 4.5. Finally, almost perfect correlation between instruments was observed ( = 0.999, most likely positive 100/0/0). Chronojump can be regarded as a sensitive instrument to detect changes in jump height performance over the possible noise around the measure. The results supported the open-source jump mat to be a useful, valid and reliable, low-cost testing device to monitor variations in vertical jumping performance.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7433325PMC
http://dx.doi.org/10.5114/biolsport.2020.95636DOI Listing

Publication Analysis

Top Keywords

jump mat
16
open-source jump
12
positive 100/0/0
8
jump
7
instruments
5
reliability validity
4
validity chronojump
4
chronojump open-source
4
mat
4
mat system
4

Similar Publications

Sprint and jump performance are determined by localized BIA - an ecological study in track and field adolescent athletes.

BMC Sports Sci Med Rehabil

November 2024

Laboratory of Growth and Development, Center for Investigation in Pediatrics, School of Medical Sciences, State University of Campinas (UNICAMP), Campinas, Sao Paulo, Brazil.

Background: Raw data obtained through bioelectrical impedance analysis (BIA) have been applied in different populations to assess body fluids and cell integrity. Assessing raw BIA parameters in specific muscles is an emerging method for evaluating muscle function. We investigated the associations of the BIA-derived variables of resistance (R), reactance (Xc) and phase angle (PhA) measured through whole-body (WB) and muscle-localized (ML) methods with performance in the countermovement jump (CMJ) and 50-meter (m) sprint.

View Article and Find Full Text PDF

Measuring countermovement jump (CMJ) height accurately is essential for evaluating lower-body explosive power in athletes and other active populations. With technological advancements, various portable tools have been developed for this purpose, including force platforms, contact mats, and video-based software. This study aimed to (a) investigate the test-retest reliability of the KINVENT K-Deltas force platform for CMJ height measurement and (b) compare its accuracy with a contact mat (Chronojump, Spain) and a video-based software (My Jump app, version 3).

View Article and Find Full Text PDF

Background: Lateral ankle sprain (LAS) is one of the most common types of injury in football (soccer). Normative baseline data of performance tests for Return to Play (RTP) decision are still lacking.

Purpose: The primary aim of this study was to generate baseline values for uninjured elite youth football players for a multifactorial RTP assessment and compare with previously published data.

View Article and Find Full Text PDF

While previous studies have explored a range of factors governing the optimal use of caffeine (CAF) in athletes, limited research has explored how time of day (TOD) affects the ergogenic effects of various CAF dosages on physical performance. This study aimed to increase knowledge about how different recommended CAF doses (3 mg/kg vs. 6 mg/kg) ingested at different TODs affected maximal high-intensity physical performance and the perception of potential side effects in female athletes.

View Article and Find Full Text PDF

Purpose: The aim of this study was to assess the concurrent validity of a contact mat against force plates to measure jump height in countermovement jump (CMJ) and squat jump (SJ) in professional soccer players.

Methods: 23 male professional soccer players performed the CMJ and SJ, which were concurrently recorded using a portable contact mat (SmartJump) and a portable dual force plate system (ForceDecks). Equivalence testing between both systems (contact mat vs.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!