Study Design.: Retrospective cohort study.

Objectives: To clinically evaluate saphenous nerve somatosensory-evoked potentials (SSEPs) as a reliable and predictable way to detect upper lumbar plexus injury intraoperatively during lateral lumbar trans-psoas interbody fusion (LLIF).

Methods: Saphenous nerve SSEPs were obtained by stimulation of inferior medial thigh with needle electrodes and recording from transcranial potentials. The primary outcome was measured by testing reproducibility of SSEPs at baseline, changes during the procedure, and relevance to standard modalities. Significant SSEP changes were compared with actual postoperative nerve complications. The sensitivity and specificity of saphenous SSEPs to detect postoperative lumbar plexus nerve injury was calculated.

Results: A total of 62 patients were included in the study. Reliable saphenous SSEPs were recorded on the LLIF approach side in 52/62 patients. Persistent saphenous SSEP reduction of amplitude of >50% in 6 cases was observed during expansion of the tubular retractor or during the procedure. Two of 6 patients postoperatively had femoral nerve sensory deficits, and 5 of 6 patients had mild femoral nerve motor weakness, all of which resolved at an average of 12 weeks postoperatively (range 2-24 weeks). One patient had saphenous SSEP changes but demonstrated intraoperative recovery and had no postoperative clinical deficits. Saphenous SSEPs demonstrated 52% to 100% sensitivity and 90% to 100% specificity for detecting postoperative femoral nerve complications.

Conclusion: Saphenous SSEPs can be used to detect electrophysiological changes to prevent femoral nerve injury during LLIF. Intraoperative SSEP recovery after amplitude reduction or loss may be a prognostic factor for final clinical outcome.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8165933PMC
http://dx.doi.org/10.1177/2192568220922979DOI Listing

Publication Analysis

Top Keywords

saphenous sseps
16
femoral nerve
16
saphenous nerve
12
saphenous
9
nerve somatosensory-evoked
8
somatosensory-evoked potentials
8
interbody fusion
8
nerve
8
lumbar plexus
8
ssep changes
8

Similar Publications

Transabdominal motor evoked potential neuromonitoring of lumbosacral spine surgery.

Spine J

September 2024

Department of Orthopedics, Houston Methodist Health System, 6560 Fannin Street, Houston, TX 77030, USA.

Background Context: Transcranial Motor Evoked Potentials (TcMEPs) can improve intraoperative detection of femoral plexus and nerve root injury during lumbosacral spine surgery. However, even under ideal conditions, TcMEPs are not completely free of false-positive alerts due to the immobilizing effect of general anesthetics, especially in the proximal musculature. The application of transcutaneous stimulation to activate ventral nerve roots directly at the level of the conus medularis (bypassing the brain and spinal cord) has emerged as a method to potentially monitor the motor component of the femoral plexus and lumbosacral nerves free from the blunting effects of general anesthesia.

View Article and Find Full Text PDF

Study Design: Retrospective review.

Objective: Assess the feasibility of saphenous nerve somatosensory evoked potentials (SN-SSEP) monitoring in lumbar spine surgeries.

Background Context: SN-SSEPs have been proposed for detecting lumbar plexus and femoral nerve injury during lateral lumbar surgery where tibial nerve (TN) SSEPs alone are insufficient.

View Article and Find Full Text PDF

Purpose: To assess whether saphenous somatosensory-evoked potentials (saphSSEP) monitoring may provide predictive information of femoral nerve health during prone lateral interbody fusion (LIF) procedures.

Methods: Intraoperative details were captured prospectively in consecutive prone LIF surgeries at a single institution. Triggered electromyography was used during the approach; saphSSEP was monitored throughout using a novel system that enables acquisition of difficult signals and real-time actionable feedback facilitating intraoperative intervention.

View Article and Find Full Text PDF

Objective: To review the evidence for the use of electromyography (EMG), motor-evoked potentials (MEPs), and somatosensory-evoked potentials (SSEPs) intraoperative neuromonitoring (IONM) strategies during lateral lumbar interbody fusion (LLIF), as well as discuss the limitations associated with each technique.

Methods: A comprehensive review of the literature and compilation of findings relating to clinical studies investigating the efficacy of EMG, MEP, SSEP, or combined IONM strategies during LLIF.

Results: The evidence for the use of EMG is mixed with some studies demonstrating the efficacy of EMG in preventing postoperative neurologic injuries and other studies demonstrating a high rate of postoperative neurologic deficits with EMG monitoring.

View Article and Find Full Text PDF

Lateral lumbar interbody fusion procedures are performed with multimodality neuromonitoring of the femoral nerve to prevent lumbosacral plexus and peripheral nerve injury from positioning, dilation, retraction, and hardware implantation. The integrity of the femoral nerve can be continuously assessed during these procedures by Somatosensory Evoked Potentials of the Saphenous nerve (Sn-SSEPs). Sn-SSEPs are technically challenging to acquire and necessitate advanced troubleshooting skills with a more rigid anesthetic regimen and physiological parameters.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!