Background: We hypothesized that when the posterior cruciate ligament (PCL) is found deficient at total knee arthroplasty (TKA), using an anterior-stabilized (AS) tibial insert would provide similar function and survivorship when compared to using a more traditional cruciate-retaining (CR) bearing when the (PCL) is balanced.

Methods: A total of 1731 TKAs were performed using the same TKA design. Of them, 868 TKAs had a standard CR insert implanted (CR-S), 480 TKAs used a lipped CR insert (CR-L), and 383 TKAs used an AS insert. If the PCL was considered nonfunctional or absent, an AS bearing was placed. When the PCL was balanced, a CR-S or CR-L bearing was used. Follow-up was performed using the Knee Society scoring system. Kaplan-Meier survivorship was used with failure defined as aseptic loosening.

Results: At final follow-up, there were no significant differences in knee flexion, pain, function, or stair scores. Walking scores were significantly lower in the AS group. Posterior instability was higher in the CR-S group, whereas the manipulation rate was highest in the CR-L group (1.7%, 1.3%, and 0% for CR-L, CR-S, and AS groups, respectively). Kaplan-Meier survivorship at 5 years demonstrated no significant difference between the 3 groups (99% 100%, and 99% for CR-S, CR-L, and AS groups, respectively).

Conclusion: Using an AS insert provided similar function and 5-year survivorship as compared to using a CR-S and CR-L tibial insert when the PCL was balanced. Using an ultracongruent AS dished tibial component appears to be a reasonable option when the PCL is completely released or found deficient at operation.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.arth.2020.08.016DOI Listing

Publication Analysis

Top Keywords

cr-s cr-l
12
total knee
8
knee arthroplasty
8
tibial insert
8
survivorship compared
8
bearing pcl
8
insert pcl
8
pcl balanced
8
kaplan-meier survivorship
8
pcl
6

Similar Publications

Background: We hypothesized that when the posterior cruciate ligament (PCL) is found deficient at total knee arthroplasty (TKA), using an anterior-stabilized (AS) tibial insert would provide similar function and survivorship when compared to using a more traditional cruciate-retaining (CR) bearing when the (PCL) is balanced.

Methods: A total of 1731 TKAs were performed using the same TKA design. Of them, 868 TKAs had a standard CR insert implanted (CR-S), 480 TKAs used a lipped CR insert (CR-L), and 383 TKAs used an AS insert.

View Article and Find Full Text PDF

Which total knee replacement implant should I pick? Correcting the pathology: the role of knee bearing designs.

Bone Joint J

November 2013

Joint Implant Surgeons, 7277 Smith's Mill Road, Suite 200 New Albany, Ohio 43054, USA.

Debate has raged over whether a cruciate retaining (CR) or a posterior stabilised (PS) total knee replacement (TKR) provides a better range of movement (ROM) for patients. Various sub-sets of CR design are frequently lumped together when comparing outcomes. Additionally, multiple factors have been proven to influence the rate of manipulation under anaesthetic (MUA) following TKR.

View Article and Find Full Text PDF

We report the synthesis of the novel heterometallic complex [Fe(3)Cr(L)(2)(dpm)(6)]⋅Et(2)O (Fe(3)CrPh) (Hdpm=dipivaloylmethane, H(3)L=2-hydroxymethyl-2-phenylpropane-1,3-diol), obtained by replacing the central iron(III) atom by a chromium(III) ion in an Fe(4) propeller-like single-molecule magnet (SMM). Structural and analytical data, high-frequency EPR (HF-EPR) and magnetic studies indicate that the compound is a solid solution of chromium-centred Fe(3)Cr (S=6) and Fe(4) (S=5) species in an 84:16 ratio. Although SMM behaviour is retained, the |D| parameter is considerably reduced as compared with the corresponding tetra-iron(III) propeller (D=-0.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!