A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Catheter-based Arterial Input Function Determination for Myocardial Perfusion Measurements. | LitMetric

Catheter-based Arterial Input Function Determination for Myocardial Perfusion Measurements.

Z Med Phys

Department of Radiology - Medical Physics, University Medical Center Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany. Electronic address:

Published: February 2021

The quantification of myocardial perfusion with contrast agent (CA) tracers requires the precise knowledge of the arterial input function (AIF). In this study a method for MR-guided vascular interventions is evaluated that determines the AIF via an active tracking catheter during targeted CA injection. A phantom experiment with a dialysis filter was conducted to measure the AIF using an active catheter and a dynamic image series as reference. To compensate for dilution and coil sensitivity effects, correction methods were developed for the catheter-based AIF determination. From the dynamic MR measurements in the perfusion phantom quantitative perfusion maps were calculated by a deconvolution of the measured CA concentration with the AIF, and additional flow measurements were used to normalize the perfusion map. The signal-time-curves of the measured AIF using the catheter-based and imaging-based methods agree while the absolute values differ by a scaling factor of about 9. After normalization to the surrounding flow, both perfusion techniques are in excellent agreement. Catheter-based AIF measurements are feasible but require an additional normalization which can be determined from a flow measurement. The technique might enable faster perfusion measurements during cardiovascular interventions.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.zemedi.2020.07.004DOI Listing

Publication Analysis

Top Keywords

arterial input
8
input function
8
myocardial perfusion
8
perfusion measurements
8
aif active
8
catheter-based aif
8
perfusion
7
aif
7
measurements
5
catheter-based
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!