Purpose: To report a single-center series of patients with type B aortic dissection treated with the Multilayer Flow Modulator (MFM).
Materials And Methods: Over a 36-month period, 23 patients (median age 53 years; 20 men) with complicated type B aortic dissections (2 acute, 5 subacute, and 16 chronic) were treated with the MFM. Primary endpoints of rupture or dissection-related death, overall mortality, and reintervention were evaluated using the Kaplan-Meier method; estimates for freedom from the endpoints are reported with the 95% confidence interval (CI). Secondary outcomes included technical success, adverse events, and aortic remodeling. Clinical and imaging data were collected preoperatively, directly postoperatively, and annually to 36 months for analysis using computational fluid dynamics (CFD).
Results: Initial technical success was 91.3%. The estimates of the endpoints at 12 months were 100% for freedom from rupture or aortic-related death, 95.7% for freedom from overall mortality, and 91.3% for freedom from reintervention. No device-related neurological or systemic complications occurred, and no additional reinterventions were needed during follow-up. A total of 144 branches overstented by the MFM remained patent. Morphologic analysis of the aortic dissection showed progressive true lumen volume increase (75.9%, p<0.001) with concomitant false lumen volume decrease (42.8%, p<0.001); the CFD analyses showed increased laminar flow.
Conclusion: In the current series, the MFM provided a safe and feasible treatment option for complicated acute, subacute, and chronic type B aortic dissections, with high technical success, low mortality, and active aortic remodeling. Further studies should elucidate the long-term safety of the MFM and its effectiveness in a larger patient cohort.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7816551 | PMC |
http://dx.doi.org/10.1177/1526602820950720 | DOI Listing |
Ann Vasc Surg
January 2025
Institute of Cardiac and Aortic Disorders, SRM Institutes for Medical Science (SIMS Hospitals), Chennai, India.
Background: Nonocclusive mesenteric ischemia (NOMI), a subtype of acute mesenteric ischemia, is primarily caused by mesenteric arterial vasoconstriction and decreased vascular resistance, leading to impaired intestinal perfusion.Commonly observed after cardiac surgery, NOMI affects older patients with cardiovascular or systemic diseases, accounting for 20-30% of acute mesenteric ischemia cases with a mortality rate of ∼50%. This review explores NOMI's pathophysiology, clinical implications in aortic dissection, and the unmet needs in diagnosis and management, emphasizing its prognostic significance.
View Article and Find Full Text PDFAnn Vasc Surg
January 2025
Division of Vascular Surgery, Penn State Milton S. Hershey Medical Center, Hershey, PA.
Objectives: The population in the U.S., and across the world is aging rapidly which warrants an assessment of the safety of surgical approaches in elderly individuals to better risk stratify and inform surgeons' decision making for optimal patient care.
View Article and Find Full Text PDFEur J Cardiothorac Surg
January 2025
Department of Cardiothoracic Surgery, Maastricht University Medical Centre (MUMC+), Netherlands.
Objectives: Previous analyses of the volume-outcome relationship have focused on short-term outcomes such as early mortality. The current study aims to update a novel statistical methodology, facilitating the evaluation of the relation between procedural volume and time-to-event outcomes such as long-term survival, using surgery for acute type A aortic dissection as an illustrative example.
Methods: This study employed an existing dataset of type A dissection outcomes, retrieved from literature.
Gen Thorac Cardiovasc Surg
January 2025
Department of Cardiovascular Surgery, Nerima Hikarigaoka Hospital, 1-5-2, Hikarigaoka, Nerima-ku, Tokyo, Japan.
Objective: Branched prostheses are used to treat aortic arch with dissection. However, changes in the neck vessel geometry and diameter after dissection are not well known. We aimed to evaluate neck vessels geometry and changes in diameter with dissection.
View Article and Find Full Text PDFJ Endovasc Ther
January 2025
Department of Vascular Surgery, Swiss Aortic Center Bern, Inselspital, University Hospital of Bern, University of Bern, Bern, Switzerland.
Purpose: To perform a systematic review and meta-analysis of the outcomes of Anaconda fenestrated endograft for the treatment of complex abdominal aortic aneurysms (cAAA).
Material And Methods: A systematic search of all the literature reported until May 2024 was performed according to the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines. The pooled 30-day mortality rate, technical success rate, reintervention rate as well as bridging stent occlusion rate, and corresponding 95% confidence intervals (CIs) were estimated using fixed or random effect methods.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!