A high sensitivity force sensor based on dielectric microspheres in vacuum, optically trapped by a single, upward-propagating laser beam, is described. Off-axis parabolic mirrors are used both to focus the 1064 nm trapping beam and to recollimate it to provide information on the horizontal position of the microsphere. The vertical degree of freedom is readout by forming an interferometer between the light retroreflected by the microsphere and a reference beam, hence eliminating the need for auxiliary beams. The focus of the trapping beam has a 1/E radius of 3.2 µm and small non-Gaussian tails, suitable for bringing devices close to the trapped microsphere without disturbing the optical field. Electrodes surrounding the trapping region provide excellent control of the electric field, which can be used to drive the translational degrees of freedom of a charged microsphere and the rotational degrees of freedom of a neutral microsphere, coupling to its electric dipole moment. With this control, the charge state can be determined with single electron precision, the mass of individual microspheres can be measured, and empirical calibrations of the force sensitivity can be made for each microsphere. A force noise of <1 × 10 N/Hz, which is comparable to previous reports, is measured on all three degrees of freedom for 4.7 µm diameter, 84 pg silica microspheres. Various devices have been brought within 1.6 µm of the surface of a trapped microsphere. Metrology in the trapping region is provided by two custom-designed microscopes providing views in the horizontal and one of the vertical planes. The apparatus opens the way to performing high sensitivity three-dimensional force measurements at a short distance.

Download full-text PDF

Source
http://dx.doi.org/10.1063/5.0011759DOI Listing

Publication Analysis

Top Keywords

high sensitivity
8
trapping beam
8
degrees freedom
8
microsphere
7
sensitivity levitated
4
levitated microsphere
4
microsphere apparatus
4
apparatus short-distance
4
force
4
short-distance force
4

Similar Publications

Machine learning (ML) is a powerful tool for the automated data analysis of molecular dynamics (MD) simulations. Recent studies showed that ML models can be used to identify protein-ligand unbinding pathways and understand the underlying mechanism. To expedite the examination of MD simulations, we constructed PathInHydro, a set of supervised ML models capable of automatically assigning unbinding pathways for the dissociation of gas molecules from [NiFe] hydrogenases, using the unbinding trajectories of CO and H from [NiFe] hydrogenase as a training set.

View Article and Find Full Text PDF

Soft capacitive sensors are widely utilized in wearable devices, flexible electronics, and soft robotics due to their high sensitivity. However, they may suffer delamination and/or debonding due to their low interfacial toughness. In addition, they usually exhibit a small measurement range resulting from their limited stiffness variation range.

View Article and Find Full Text PDF

Silver nanowire (Ag NW)-based elastic conductors have been considered a promising candidate for key stretchable electrodes in wearable devices. However, the weak interface interaction of Ag NWs and elastic substrates leads to poor durability of electronic devices. For everyday usage, an additional self-healing ability is required to resist scratching and damage.

View Article and Find Full Text PDF

Exploring esophagogastric junction morphology and contractile integral: implications for refractory gastroesophageal reflux disease pathophysiology.

Scand J Gastroenterol

January 2025

Department of Gastroenterology and Hepatology, Zhongshan Hospital, Fudan University, Xiamen Branch, Xiamen, China.

Background: Evaluate the clinical significance of esophagogastric junction (EGJ) morphology and esophagogastric junction contractile integral (EGJ-CI) in refractory gastroesophageal reflux disease (RGERD) patients.

Methods: From June 2021 to June 2023, 144 RGERD patients underwent comprehensive evaluation, recording symptom scores, demographic data. GERD classification (NERD or RE, A-D) was based on endoscopic findings.

View Article and Find Full Text PDF

Association of smartphone overuse and neck pain: a systematic review and meta-analysis.

Postgrad Med J

January 2025

Department of Orthopedics, Hualien Tzu Chi Hospital, Buddhist Tzu Chi Medical Foundation, Hualien, Taiwan.

Background: Smartphone overuse is associated with both psychological and physical health problems, including depression and musculoskeletal disorders. However, the association between smartphone overuse and neck pain remains unclear. We performed a meta-analysis to examine the relation between smartphone overuse and neck pain, and to identify high-risk usage patterns.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!