Purpose: To test the performances of a volumetric arc technique named ViTAT (Virtual Tangential-fields Arc Therapy) mimicking tangential field irradiation for whole breast radiotherapy.
Methods: ViTAT plans consisted in 4 arcs whose starting/ending position were established based on gantry angle distribution of clinical plans for right and left-breast. The arcs were completely blocked excluding the first and last 20°. Different virtual bolus densities and thicknesses were preliminarily evaluated to obtain the best plan performances. For 40 patients with tumor laterality equally divided between right and left sides, ViTAT plans were optimized considering the clinical DVHs for OARs (resulting from tangential field manual planning) to constrain them: ViTAT plans were compared with the clinical tangential-fields in terms of DVH parameters for both PTV and OARs.
Results: Distal angle values were suggested in the ranges [220°,240°] for the right-breast and [115°,135°] for the left-breast cases; medial angles were [60°,40°] for the right side and [295°,315°] for the left side, limiting the risk of collision. The optimal virtual bolus had -500 HU density and 1.5 cm thickness. ViTAT plans generated dose distributions very similar to the tangential-field plans, with significantly improved PTV homogeneity. The mean doses of ipsilateral OARs were comparable between the two techniques with minor increase of the low-dose spread in the range 2-15 Gy (few % volume); contralateral OARs were slightly better spared with ViTAT.
Conclusion: ViTAT dose distributions were similar to tangential-fields. ViTAT should allow automatic plan optimization by developing knowledge-based DVH prediction models of patients treated with tangential-fields.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.ejmp.2020.08.011 | DOI Listing |
Phys Med
September 2022
Medical Physics Department, Veneto Institute of Oncology IOV - IRCCS, Padua, Italy.
Breast cancer is the most frequently diagnosed tumor in pregnant women and radiation therapy should carefully be weighted up because of the dose to the fetus. The aim of this study was to investigate fetal dose in a patient treated with Virtual Tangential-fields Arc Therapy (ViTAT), an innovative technique for whole breast irradiation. Optically stimulated luminescence detectors (OSLDs) were calibrated on a Varian TrueBeam linac, with both a 6X and 6XFFF beam quality, and used for out-of-field measurements.
View Article and Find Full Text PDFFront Oncol
August 2021
Medical Physics, San Raffaele Scientific Institute, Milano, Italy.
Purpose: To implement Knowledge Based (KB) automatic planning for right and left-sided whole breast treatment through a new volumetric technique (ViTAT, Virtual Tangential-fields Arc Therapy) mimicking conventional tangential fields (TF) irradiation.
Materials And Method: A total of 193 clinical plans delivering TF with wedged or field-in-field beams were selected to train two KB-models for right(R) and left(L) sided breast cancer patients using the RapidPlan (RP) tool implemented in the Varian Eclipse system. Then, a template for ViTAT optimization, incorporating individual KB-optimized constraints, was interactively fine-tuned.
Phys Med
September 2020
Medical Physics, San Raffaele Hospital Scientific Institute, Milan, Italy. Electronic address:
Purpose: To test the performances of a volumetric arc technique named ViTAT (Virtual Tangential-fields Arc Therapy) mimicking tangential field irradiation for whole breast radiotherapy.
Methods: ViTAT plans consisted in 4 arcs whose starting/ending position were established based on gantry angle distribution of clinical plans for right and left-breast. The arcs were completely blocked excluding the first and last 20°.