Purpose: To compare local ganglion cell-inner plexiform layer (GCIPL) thickness measurements between 2 OCT devices and to explore factors that may influence the difference in measurements.

Design: Cross-sectional study.

Participants: Sixty-nine glaucoma eyes (63 patients) with evidence of central damage or mean deviation (MD) of -6.0 dB or worse on a 24-2 visual field (VF).

Methods: Cirrus and Spectralis OCT macular volume scans were exported, data from the central 20° of both OCT devices were centered and aligned, and 50 × 50 arrays of 0.4° × 0.4° superpixels were created. We estimated nonparametric (Spearman's) correlations and used Bland-Altman plots to compare GCIPL thickness measurements between the two OCTs at the superpixel level. Factors that may have influenced the differences between thickness measurements between the two devices were explored with linear mixed models.

Main Outcome Measures: Pooled and individual-eye Spearman's correlation and agreement between thickness measurements from the two devices.

Results: The median 24-2 VF MD was -6.8 dB (interquartile range [IQR], -4.9 to -12.3 dB). The overall pooled Spearman's correlation between the two devices for all superpixels and eyes was 0.97 (P < 0.001). The median within-eye correlation coefficient was 0.72 (IQR, 0.59-0.79). Bland-Altman plots demonstrated a systematic bias in most individual eyes, with Spectralis GCIPL measurements becoming larger than Cirrus measurements with increasing superpixel thickness. The average superpixel thickness and distance to the fovea influenced the thickness difference between the two devices in multivariate models (P < 0.001).

Conclusions: Local macular thickness measurements from the Spectralis and Cirrus devices are highly correlated, but not interchangeable. Differences in thickness measurements between the two devices are influenced by the location of superpixels and their thickness.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7914265PMC
http://dx.doi.org/10.1016/j.ogla.2020.08.012DOI Listing

Publication Analysis

Top Keywords

thickness measurements
24
oct devices
12
thickness
11
local macular
8
macular thickness
8
devices
8
gcipl thickness
8
measurements
8
bland-altman plots
8
differences thickness
8

Similar Publications

Sulfur dioxide exposure of mice induces peribronchiolar fibrosis-A defining feature of deployment-related constrictive bronchiolitis.

PLoS One

January 2025

Research Service and Pulmonary Section Medical Service, Veterans Affairs Ann Arbor Health System, Ann Arbor, Michigan, United States of America.

Deployment-related constrictive bronchiolitis (DRCB) has emerged as a health concern in military personnel returning from Southwest Asia. Exposure to smoke from a fire at the Al-Mishraq sulfur enrichment facility and/or burn pits was reported by a subset of Veterans diagnosed with this disorder. DRCB is characterized by thickening and fibrosis of small airways (SA) in the lung, but whether these are related to toxin inhalation remains uncertain.

View Article and Find Full Text PDF

Objectives: To evaluate the value of ultrasound (US) and shear wave velocity (SWV) to assess muscle in postmenopausal women with osteosarcopenia (OSP).

Methods: This study included 145 postmenopausal women, comprising 115 osteopenia/osteoporosis participants without sarcopenia (OP alone) and 30 OSP participants. All received the evaluation of bone mineral density (BMD), appendicular skeletal muscle mass index (ASMI), handgrip strength, calf circumference, 6-meter walking speed, and 5-time chair stand test.

View Article and Find Full Text PDF

Organic photodetectors (OPDs) are key devices for monitoring vital signs, such as heart rate and blood oxygen level. For realizing the long-term measurement of biosignals, stable operation is essential. To improve the stability of OPDs, it is important to analyze each layer to understand the degradation mechanism.

View Article and Find Full Text PDF

Purpose: A human model able to simulate the manifestation of corneal endothelium decompensation could be advantageous for wound healing and future cell therapy assessment. The study aimed to establish an ex vivo human cornea endothelium wound model where endothelium function can be evaluated by measuring corneal thickness changes.

Methods: The human cornea was maintained in an artificial anterior chamber, with a continuous culture medium infusion system designed to sustain corneal endothelium and epithelium simultaneously.

View Article and Find Full Text PDF

Innovative Method for Reliable Measurement of PEM Water Electrolyzer Component Resistances.

Small Methods

January 2025

Forschungszentrum Juelich GmbH, Institute of Energy Technologies, IET-4, Electrochemical Process Engineering, 52425, Juelich, Germany.

Understanding the sheet resistance of porous electrodes is essential for improving the performance of polymer electrolyte membrane (PEM) water electrolyzers and related technologies. Despite its importance, existing methods often fail to provide reliable and comprehensive data, especially for porous materials with complex morphologies and non-uniform thicknesses. This study introduces a robust and straightforward method for determining the sheet resistance of porous electrodes using a novel probe concept based on industrial printed circuit board (PCB) technology.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!