A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Local intravascular effects of the nitinol wire blood clot filter. | LitMetric

To determine the biocompatibility and thrombogenicity of nitinol blood clot filters, we inserted 27 nitinol wire devices into the venae cavae of 16 dogs and one sheep and studied the results angiographically and at autopsy after periods of one week to four years. Filter shape, location in the vena cava, wire cleaning procedure and wire surface finish were varied. All 18 cleaned nitinol wire filters remained patent by venogram, although some showed small venographic filling defects caused by adherent organized thrombi. Filters in larger veins tended to have less thrombus. Surface polishing and filter shape had no observable effect on thrombogenicity. Histologic study revealed patchy chronic inflammation at the surface of uncleaned filters but only benign fibrous tissue reaction for the cleaned filters. Neointimal tissue overgrowth was observed where nitinol wire contacted the wall of the vena cava. Two filters implanted for four years had no appreciable weight loss caused by corrosion. Platelet adhesion and plasma coagulation effects of nitinol wire were tested in vitro in human blood and found to be similar to those of stainless steel, which is used in comparable devices. These encouraging results suggest that nitinol may be a promising material for human intravascular prosthetic applications.

Download full-text PDF

Source
http://dx.doi.org/10.1097/00004424-198804000-00009DOI Listing

Publication Analysis

Top Keywords

nitinol wire
20
effects nitinol
8
blood clot
8
filter shape
8
vena cava
8
nitinol
7
wire
7
filters
6
local intravascular
4
intravascular effects
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!