A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Acute radial head replacement with bipolar prostheses: midterm results. | LitMetric

Acute radial head replacement with bipolar prostheses: midterm results.

Eur J Orthop Surg Traumatol

Department of Surgery, Orthopaedic Clinic, Parma University Hospital, via Gramsci 14, 43100, Parma, Italy.

Published: February 2021

In irreparable radial head fractures, especially if primary stabilizers of the elbow are damaged, the prosthetic replacement prevents instability and stiffness. Concerns have arisen over the use of bipolar press-fit prostheses due to the frequent finding of osteolysis and the risk of instability if compared to monopolar implants. Our aim was to assess midterm clinical and radiological outcomes of bipolar implants and the influence of osteolysis on proximal pain. Seventeen patients with irreparable fractures of the radial head, treated in acute with the same prosthetic model (rHEAD recon SBI/Stryker) between January 2015 and December 2018, were enrolled. Clinical assessment was performed using MEPS and DASH scores; a radiographic study was done to identify heterotopic ossifications and periprosthetic osteolysis. Outcomes at the last follow-up, according to MEPS, were excellent in 10 cases, good in 5 and fair in 2; none of the patients had severe pain or instability. In 3 cases, it was necessary to remove the implant, mainly because of early loosening. Radiological findings of osteolysis were detected in 9 cases, but no statistical correlation was found with MEPS and proximal pain. The use of bipolar implants is reliable if an accurate repair of ligament tears is performed and provides a good stability. Nevertheless, the risk of early aseptic loosening in uncemented implants is not negligible, and the follow-up of the patient must be strict. Late osteolysis does not seem to have clinical relevance, but further prospective studies are necessary to clarify this topic.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7875843PMC
http://dx.doi.org/10.1007/s00590-020-02774-4DOI Listing

Publication Analysis

Top Keywords

radial head
12
bipolar implants
8
proximal pain
8
osteolysis
5
acute radial
4
head replacement
4
bipolar
4
replacement bipolar
4
bipolar prostheses
4
prostheses midterm
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!