This paper presents experimental and analytical studies on the time-varying behavior of an NI (no-insulation) high-temperature superconductor pancake coil, alone or magnetically coupled to an external coil. An NI coil and another insulated coil (as an external), both of identical winding i.d. and number of turns, were fabricated. Another external coil used in this study was a 300-mm/5-T low-temperature superconductor magnet. An equivalent circuit model is proposed to simulate the NI coil, and the external coil, under time-varying conditions. Good agreement between experiment and simulation shows that the proposed equivalent circuit model is valid to characterize the time-varying electromagnetic behavior of an NI coil, alone or magnetically coupled to an external coil.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7453512PMC
http://dx.doi.org/10.1109/tasc.2013.2240756DOI Listing

Publication Analysis

Top Keywords

external coil
20
coil
10
coil time-varying
8
coil magnetically
8
magnetically coupled
8
coupled external
8
coil external
8
equivalent circuit
8
circuit model
8
external
6

Similar Publications

This study employed a magnetic field to investigate the impact of myoglobin (Mb) oxidation (0-20 mmol/L HO) on the gel properties of myofibrillar protein (MP). The results indicated that magnetic field could further facilitate the rearrangement of the Mb structure, resulting in the transfer of its internal reactive groups to the external environment. This contributed to hydration and cross-linking between MP.

View Article and Find Full Text PDF

This study aimed to evaluate the efficacy of the single-energy metal artifact reduction (SEMAR) algorithm in reducing metal artifacts and enhancing image quality in contrast-enhanced computed tomography (CT) for patients undergoing endovascular aneurysm repair (EVAR) with coil embolization. Thirty-eight patients (mean age 81.0 ± 6 years; 31 men, 7 women) who underwent contrast-enhanced CT following EVAR and internal iliac artery coil embolization between September 2022 and May 2023 were retrospectively analyzed.

View Article and Find Full Text PDF

Fiber-based strain sensors, as wearable integrated devices, have shown substantial promise in health monitoring. However, current sensors suffer from limited tunability in sensing performance, constraining their adaptability to diverse human motions. Drawing inspiration from the structure of the spiranthes sinensis, this study introduces a unique textile wrapping technique to coil flexible silver (Ag) yarn around the surface of multifilament elastic polyurethane (PU), thereby constructing a helical structure fiber-based strain sensor.

View Article and Find Full Text PDF

Purpose: To investigate the safety and efficacy of endovascular embolization combined with external drainage for poor-grade ruptured cerebral aneurysms and risk factors.

Materials And Methods: Forty-six patients with poor-grade ruptured cerebral aneurysms treated with endovascular embolization combined with decompressive craniectomy and drainage were retrospectively enrolled.

Results: Coil embolization alone was performed in 29 (63.

View Article and Find Full Text PDF

This work presents the design, fabrication, and rigorous validation of a flexible, wireless, capacitive pressure sensor for the full-range continuous monitoring of ventricular pressure. The proposed system consists of an implantable set and an external readout device; both modules were designed to form an RCL resonant circuit for passive, wireless pressure sensing and signal retrieving. Using surface micromachining and flexible electronics techniques, a two-variable capacitor array and a dual-layer planar coil were integrated into a flexible ergonomic substrate, avoiding hybrid-like connections in the implantable set.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!