Background: MRI of lung parenchyma is challenging because of the rapid decay of signal by susceptibility effects of aerated lung on routine fast spin-echo sequences.

Objective: To assess lung signal intensity in children on ultrashort echo-time sequences in comparison to a fast spin-echo technique.

Materials And Methods: We conducted a retrospective study of lung MRI obtained in 30 patients (median age 5 years, range 2 months to 18 years) including 15 with normal lungs and 15 with cystic fibrosis. On a fast spin-echo sequence with radial readout and an ultrashort echo-time sequence, both lungs were segmented and signal intensities were extracted. We compared lung-to-background signal ratios and histogram analysis between the two patient cohorts using non-parametric tests and correlation analysis.

Results: On ultrashort echo-time the lung-to-background ratio was age-dependent, ranging from 3.15 to 1.33 with high negative correlation (R = -0.86). Signal in posterior dependent portions of the lung was 18% and 11% higher than that of the anterior lung for age groups 0-2 and 2-18 years, respectively. The fast spin-echo sequence showed no variation of signal ratios by age or location, with a median of 0.99 (0.98-1.02). Histograms of ultrashort echo-time slices between controls and children with aggravated cystic fibrosis with mucus plugging and wall thickening exhibited significant discrepancies that differentiated between normal and pathological lungs.

Conclusion: Signal intensity of lung on ultrashort echo-time is higher than that on fast spin-echo sequences, is age-dependent and shows a gravity-dependent anterior to posterior gradient. This signal variation appears similar to lung density described on CT.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7796870PMC
http://dx.doi.org/10.1007/s00247-020-04791-1DOI Listing

Publication Analysis

Top Keywords

ultrashort echo-time
24
fast spin-echo
20
lung
9
lung density
8
signal
8
signal intensity
8
cystic fibrosis
8
spin-echo sequence
8
signal ratios
8
ultrashort
6

Similar Publications

Objective: This study aims to evaluate the efficacy of two free-breathing magnetic resonance imaging (MRI) sequences-spiral ultrashort echo time (spiral UTE) and radial volumetric interpolated breath-hold examination (radial VIBE).

Methods: Patients were prospectively enrolled between February 2021 and September 2022. All participants underwent both 3T MRI scanning, utilizing the radial VIBE sequence and spiral UTE sequence, as well as standard chest CT imaging.

View Article and Find Full Text PDF

Osteoarthritis (OA) is heterogeneous and involves structural changes in the whole joint, such as cartilage, meniscus/labrum, ligaments, and tendons, mainly with short T2 relaxation times. Detecting OA before the onset of irreversible changes is crucial for early proactive management and limit growing disease burden. The more recent advanced quantitative imaging techniques and deep learning (DL) algorithms in musculoskeletal imaging have shown great potential for visualizing "pre-OA.

View Article and Find Full Text PDF

Differentiation of histological calcification classifications in breast cancer using ultrashort echo time and chemical shift-encoded imaging MRI.

Front Oncol

December 2024

Newcastle Magnetic Resonance Centre, Translational and Clinical Research Institute, Faculty of Medical Sciences, Newcastle University, Newcastle, United Kingdom.

Introduction: Ductal carcinoma (DCIS) accounts for 25% of newly diagnosed breast cancer cases with only 14%-53% developing into invasive ductal carcinoma (IDC), but currently overtreated due to inadequate accuracy of mammography. Subtypes of calcification, discernible from histology, has been suggested to have prognostic value in DCIS, while the lipid composition of saturated and unsaturated fatty acids may be altered in synthesis with potential sensitivity to the difference between DCIS and IDC. We therefore set out to examine calcification using ultra short echo time (UTE) MRI and lipid composition using chemical shift-encoded imaging (CSEI), as markers for histological calcification classification, in the initial step towards application.

View Article and Find Full Text PDF

Background: Quantitative assessment of cortical bone microstructure is crucial for the evaluation of osteoporosis, yet current clinical methods such as dual-energy X-ray absorptiometry (DXA) have many limitations. The quantitative assessment without radiation can be achieved by ultrashort echo time (UTE) magnetic resonance imaging (MRI), where double-echo UTE has high clinical feasibility. However, related studies have mainly focused on distal extremities, and there is a lack of studies on the proximal femur.

View Article and Find Full Text PDF

Osteochondral Abnormalities on Three-Dimensional Ultrashort Echo Time MRI Scans Are Associated with Knee Cartilage Degradation.

Radiology

December 2024

From the Department of Radiology, Hanyang University Hospital, 222-1 Wangsimni-ro, Seongdong-gu, Seoul 04763, South Korea (Sunmin Lee, Y.J.K., Seunghun Lee); Department of Radiology, Hanyang University Guri Hospital, Guri, South Korea (J.R.); Department of Radiology, Eunpyeong St Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, South Korea (H.Y.L.); Department of Radiology, University of California, Davis, Sacramento, Calif (H.J.); Biostatistics Laboratory, Medical Research Collaborating Center, Industry-University Cooperation Foundation, Hanyang University, Seoul, South Korea (H.W.T., J.K.); and Department of Pre-Medicine, College of Medicine, Hanyang University, Seoul, South Korea (J.K.).

Background The calcified cartilage layer and subchondral bone plate (SBP) contribute to osteoarthritis development. Three-dimensional (3D) ultrashort echo-time (UTE) MRI can help to evaluate calcified cartilage and SBP in various stages of cartilage degradation. Purpose To compare calcified cartilage and SBP abnormalities using 3D UTE MRI with cartilage degradation and osteochondral junction (OCJ) abnormalities observed at proton-density fast spin-echo with fat suppression (PDFS) MRI.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!