Background: Integration of intracardiac echocardiography (ICE) and 3D electroanatomic mapping (EAM) system allows transseptal punctures (TSP) without the use of fluoroscopy. Compared with fluoroscopy, ICE provides better visualization of the anatomy relevant to TSP and early recognition of complications. The aim was to evaluate efficacy and safety of entirely ICE-guided TSPs in patients who underwent fluoroless catheter ablation of left-sided tachycardias.

Methods: Consecutive 524 adult and pediatric patients referred to our institution from July 2014 to December 2019 were analyzed. Patients with cardiac implantable electronic devices (CIEDs) were also included. All procedures were performed with ICE-guided TSP combined with 3D EAM. Adverse events following TSP and within 30 days of the procedure were analyzed.

Results: Altogether 949 TSPs (363 double punctures, 76.5%) were performed in 586 fluoroless ablation procedures: 451 (77%) were ablation of atrial fibrillation or atypical flutter, 75 (12.8%) of left-sided accessory pathway, 33 (5.6%) of ventricular tachycardia, and 27 (4.6%) of focal atrial tachycardia. Forty-six (7.8%) procedures were performed in pediatric population and 36 procedures (6.1%) in patients with CIED. Only 2 TSPs were unsuccessful (2/949, 0.2%). Overall procedural complication rate was 1.9% (11/586 procedures). There was only 1 TSP-related pericardial tamponade (2/949, 0.2%). In CIED patients, there was 1 lead dislocation following TSP.

Conclusions: Entirely ICE-guided TSPs for different left-sided tachycardias can be safely and effectively performed in adult and pediatric population without the use of fluoroscopy. However, caution is advised in CIED patients due to possible lead dislocation risk.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10840-020-00858-zDOI Listing

Publication Analysis

Top Keywords

fluoroless catheter
8
catheter ablation
8
ablation left-sided
8
left-sided tachycardias
8
entirely ice-guided
8
ice-guided tsps
8
adult pediatric
8
procedures performed
8
pediatric population
8
2/949 02%
8

Similar Publications

Case Report: A novel method of needle-free transseptal puncture.

Front Cardiovasc Med

December 2024

Department of Internal Medicine, College of Medicine, National Taiwan University, Taipei, Taiwan.

Background: In the era of fluoroless catheter ablation (CA), achieving a successful transseptal puncture (TSP) presents a significant challenge. We introduce a novel technique for zero-fluoroscopy and cost-effective needle-free TSP.

Case Summary: We describe two cases where a GMS-1 guidewire (0.

View Article and Find Full Text PDF

Pulsed-field ablation for atrial fibrillation without the use of fluoroscopy.

J Interv Card Electrophysiol

August 2024

Cardiac Electrophysiology, South Denver Cardiology Associates, 1000 Southpark Drive, Littleton, CO, 80111, USA.

Introduction: Pulsed-field ablation (PFA) and fluoroless ablation (FA) are emerging techniques in contemporary in electrophysiology. With widespread use of 3D electroanatomic mapping systems and advanced intracardiac echo (ICE) imaging, fluoroless ablation has become more widely adopted. However, with the importance of tissue contact for lesion durability, initial PFA has been used with fluoroscopic guidance, but both ICE and electroanatomic mapping make fluoroless PFA feasible.

View Article and Find Full Text PDF

Pulmonary vein isolation (PVI) stands as a widely practiced cardiac ablation procedure on a global scale, conventionally guided by fluoroscopy. The concurrent application of electroanatomical mapping systems (EAMS) and intracardiac echocardiography offers a means to curtail radiation exposure. This study aimed to compare procedural outcomes between conventional and our initial zero-fluoroscopy cases in patients with paroxysmal or persistent atrial fibrillation (AF), undergoing point-by-point PVI.

View Article and Find Full Text PDF

Purpose Of The Review: Intracardiac echocardiography (ICE) provides real-time, fluoroless imaging of cardiac structures, allowing optimal catheter positioning and energy delivery during ablation procedures. This review summarizes the use of ICE in catheter ablation of atrial fibrillation (AF).

Recent Findings: Growing evidence suggests that the use of ICE improves procedural safety and facilitates radiofrequency and cryoballoon AF ablation.

View Article and Find Full Text PDF

Catheter ablation for focal atrial tachycardias during pregnancy: A systematic review.

Int J Cardiol

October 2024

Department of Clinical Electrophysiology & Cardiac Pacing, Centro Cardiologico Monzino, IRCCS, Milan, Italy; Department of Biomedical, Surgical and Dental Sciences, University of Milan, Milan, Italy.

Article Synopsis
  • - The study examines the use of catheter ablation (CA) as a treatment for focal atrial tachycardia (AT) in pregnant women, highlighting the risks of medical interventions and the potential benefits of CA, particularly with non-fluoroscopic navigation systems.
  • - A systematic literature search reviewed 278 papers, ultimately including 15 studies with 24 patients; the results showed an impressive acute success rate of 95.8% with CA, and a significant number of procedures were performed without fluoroscopy.
  • - The findings suggest that CA is a viable option for treating incessant AT during pregnancy, with minimal long-term recurrence; however, further large-scale studies are needed to better assess its safety and effectiveness.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!