Background: We hypothesized that axial-loaded magnetic resonance imaging (MRI), modified with the use of a cushion placed behind the lower back (i.e. BS-MRI method), would simulate the standing position more accurately than an axial-loaded MRI without a cushion back support (BS).
Purpose: To determine whether the BS-MRI method demonstrated similar morphologies on intervertebral disc (IVD), dural sac, and spinal curvature as those detected on 90° standing MRIs in individuals with suspected spinal stenosis.
Material And Methods: Twenty-five subjects underwent a BS-MRI, as well as axial-loaded and standing MRI studies. Outcome measures were four radiographic parameters of the lumbar spine: IVD height (DH); dural sac cross-sectional area (DCSA); and spinal curvature (i.e. lumbar lordosis [LL] and L1-L3-L5 angle [LA]).
Results: Major differences (>5%) between standing MRI and BS-MRI methods were observed in DCSA, DH, and LL. Major differences between standing and axial loaded MRIs were observed only in DCSA and LA. Although BS-MRIs demonstrate an image of the lumbar spine curvature (i.e. LA) which is closer to that when standing than axial-loaded MRIs, it is likely to overestimate both narrowing of dural sac and extent of LL.
Conclusion: Using a compression device with a BS to simulate weight-bearing on the lumbar spine is not recommended due to: (i) overestimation of the narrowing of the dural sac and extent of LL; and (ii) underestimation of loss of disc height. Supine axial-loading produced DCSA and DH which were strongly correlated with those detected with standing MRIs. Exceptions were that LL and LA were underestimated.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1177/0284185120951963 | DOI Listing |
NeuroSci
December 2024
Laboratory of Surgical Neuroanatomy (LSNA), Human Anatomy and Embryology Unit, Faculty of Medicine and Health Sciences, Universitat de Barcelona, 08036 Barcelona, Spain.
Cauda equina nerve roots may become damaged during neuraxial anesthesia, and post-puncture headache may appear in the case of cerebrospinal fluid leakage if needle tips are deformed due to bone contact when several attempts are needed. Our aim was to verify the correlation between skin-transverse process distance (st) and skin-dural sac distance (d) for calculation of optimal angles in a free visual guide and as a reference for the maximal depth to be traversed by the needle. Randomly selected ex vivo samples ( = 10) were flexed to reproduce the position of the lumbosacral spine during spinal anesthesia.
View Article and Find Full Text PDFInt Immunopharmacol
December 2024
Institute of Clinical Medicine, College of Medicine, National Cheng Kung University, Tainan, Taiwan; Clinical Medicine Research Center, National Cheng Kung University Hospital, College of Medicine, National Cheng Kung University, Tainan, Taiwan; Antibody New Drug Research Center, National Cheng Kung University, Tainan, Taiwan. Electronic address:
Background: Post-laminectomy syndrome (PLS) manifests as recurrent chronic back pain, with or without radiating leg pain, affecting 10-40% of patients following laminectomy. While surgical interventions can alleviate recurrent disc herniation or joint instability, medical management of PLS remains challenging due to unsatisfactory outcomes. Epidural fibrosis is a frequent cause of PLS, leading to nerve root tethering and dural sac compression.
View Article and Find Full Text PDFSpine (Phila Pa 1976)
December 2024
Department of Research and Innovation, Møre and Romsdal Hospital Trust, Ålesund, Norway.
Study Design: A secondary analysis of data from the NORDSTEN-spinal stenosis trial (SST).
Objective: The aim of the present study was to investigate whether the dural sac cross-sectional area (DSCA) on magnetic resonance imaging (MRI) of adjacent segments decreases after decompressive surgery due to lumbar spinal stenosis (LSS) up to 2 years postoperatively, and to investigate possible associations with baseline variables, including preoperative patient and radiological characteristics, and surgical method used.
Summary Of Background Data: Decompressive surgery for LSS is currently the most common spinal surgery procedure; however, there is limited knowledge on changes in the DSCA over time adjacent to a decompressed segment.
Acta Med Okayama
December 2024
Department of Orthopaedic Surgery, Okayama Rosai Hospital.
This report presents a new unilateral biportal endoscopic (UBE) technique for lumbar disc herniation without C-arm guidance. Lumbar disc herniation requires surgical intervention when conservative methods fail. Shifts towards minimally invasive percutaneous endoscopic lumbar discectomy, including uniportal and biportal approaches, have been hindered by challenges such as steep learning curves and reliance on radiation-intensive C-arm guidance.
View Article and Find Full Text PDFZhongguo Gu Shang
December 2024
Derpartment of Spine Surgery, Nuclear Industry 416 Hospital, Chengdu 610000, Sichuan, China.
Objective: To explore feasibility, clinical and imaging outcomes of percutaneous endoscopic interlaminar discectomy (PEID) for single level large lumbar disc herniation(LDH).
Methods: From October 2018 to March 2023, 31 patients with single level LDH treated with PEID were retrospectively analyzed. Among patients, including 18 males and 13 females, aged from 15 to 40 years old with an average of (28.