Purpose/aim: In an attempt to increase the service life of dental adhesive interfaces, more hydrolytically and enzymatically-stable methacrylate alternatives, such as methacrylamides, have been proposed. The aim of this study was to investigate polymerization behavior, as well as mechanical and biological properties of experimental adhesives containing multi-functional acrylamides.

Materials And Methods: Multi-functional acrylamides (N,N-Bis[(3-methylaminoacryl)propyl]methylamine - BMAAPMA, Tris[(2-methylaminoacryl)ethyl]amine - TMAAEA, N,N'-bis(acrylamido) 1,4-diazepane - BAADA, N,N-Diethyl-1,3-bis(acrylamido)propane - DEBAAP) or HEMA (2-Hydroxyethyl methacrylate - control) were added at 40 wt% to UDMA. 0.2 wt% DMPA and 0.4 wt% DPI-PF6 were used as initiators. Polymerization kinetics was followed in real-time in near-IR during photoactivation (320-500 nm, at 630 mW/cm). Water sorption/solubility and flexural strength/modulus were measured according to ISO 4049. H NMR was used to assess monomer degradation kinetics. MTT assay was used to assess cytotoxicity against OD-21 and DPSC cells. Biofilm formation and adhesion were assessed by Luciferase Assay and Impingement technique, respectively. Solvated adhesives (40 vol% ethanol) were used to test interfacial adhesion strength. The results were analyzed by ANOVA/Tukey's test (α = 0.05).

Results: In general, the pure methacrylate mixture had higher rate of polymerization (Rp), degree of conversion (DC) at Rp, and final DC than the acrylamides. Flexural properties after water storage decreased between 11 and 65%, more markedly for acrylamides. Interfacial bond strength was greater and more stable long-term for the newly synthesized acrylamide formulations (less than 4% reduction at 6 months) compared to the methacrylate experimental control (42% reduction at 6 months). HEMA degraded by almost 90%, while the acrylamides showed no degradation in acidic conditions. Cytotoxicity and biofilm formation, in general, were similar for all groups.

Conclusions: Despite demonstrating high water sorption, the acrylamide-containing materials had similar mechanical and biological properties and enhanced interfacial bond strength stability compared to the methacrylate control.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7530076PMC
http://dx.doi.org/10.1016/j.actbio.2020.08.026DOI Listing

Publication Analysis

Top Keywords

dental adhesive
8
adhesive interfaces
8
mechanical biological
8
biological properties
8
methacrylate control
8
biofilm formation
8
interfacial bond
8
bond strength
8
reduction months
8
compared methacrylate
8

Similar Publications

In dental practice, there are two major diseases: dental caries and periodontal disease. Although dental treatment techniques have advanced along with advances in dental materials, some diseases such as root surface caries and horizontal bone resorption have not yet achieved satisfactory treatment results. Since these diseases are infections caused by oral bacteria, we believe that materials with long-lasting antimicrobial properties would help control these diseases.

View Article and Find Full Text PDF

Objective: To evaluate the influence of different cleaning methods, surface treatments, and aging on the repair bond strength to a CAD/CAM glass-ceramic.

Materials And Methods: Forty-eight lithium disilicate CAD/CAM ceramic blocks were fabricated, sintered, and embedded in acrylic resin. After contamination with human saliva, they were divided according to the factors "Cleaning method" (Control-water/air spray, Air-particle abrasion with AlO, Ivoclean cleaning paste), "Surface treatment" (5% Hydrofluoric acid-HF + Silane, Monobond Etch & Prime-MEP), and "Aging" (thermocycling, no thermocycling).

View Article and Find Full Text PDF

Long-Term Success and Survival of Post-Endodontic Restorations Without Posts After up to18 Years: A Practice-Based Study.

J Dent

January 2025

Department of Restorative, Preventive and Pediatric Dentistry, zmk bern, University of Bern, Switzerland; Unit for Practice-based Research, School of Dental Medicine, University of Bern, Switzerland. Electronic address:

Objectives: The aim of this non-interventional, multi-center, prospective, practice-based study was, firstly, to evaluate the longevity of composite build-ups in endodontically treated teeth, treated with root canal therapy (ETT), without post placement and secondly, to identify and analyze factors influencing the success of these reconstructions.

Methods: Each of seven general dental practitioners placed up to 50 composite build-ups without additional posts in ETT. Teeth were restricted to incisors, canines and premolars.

View Article and Find Full Text PDF

Novel Foamed Magnesium Phosphate Antimicrobial Bone Cement for Bone Augmentation.

J Biomed Mater Res B Appl Biomater

January 2025

Chongqing Key Laboratory of Oral Diseases and Biomedical Sciences, Chongqing, People's Republic of China.

In dental implant surgery, infection is identified as the primary factor contributing to the failure of bone grafts. There is an urgent need to develop bone graft materials possessing antibacterial characteristics to facilitate bone regeneration. Magnesium phosphate bone cement (MPC) is highly desirable for bone regeneration due to its favorable biocompatibility, plasticity, and osteogenic capabilities.

View Article and Find Full Text PDF

Robotic Microcapsule Assemblies with Adaptive Mobility for Targeted Treatment of Rugged Biological Microenvironments.

ACS Nano

January 2025

Center for Innovation & Precision Dentistry, School of Dental Medicine, School of Engineering and Applied Science, University of Pennsylvania, Philadelphia, Pennsylvania 19104, United States.

Microrobots are poised to transform biomedicine by enabling precise, noninvasive procedures. However, current magnetic microrobots, composed of solid monolithic particles, present fundamental challenges in engineering intersubunit interactions, limiting their collective effectiveness in navigating irregular biological terrains and confined spaces. To address this, we design hierarchically assembled microrobots with multiaxis mobility and collective adaptability by engineering the potential magnetic interaction energy between subunits to create stable, self-reconfigurable structures capable of carrying and protecting cargo internally.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!