Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 143
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 143
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 209
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3098
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 574
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 488
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Severity: Warning
Message: Attempt to read property "Count" on bool
Filename: helpers/my_audit_helper.php
Line Number: 3100
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3100
Function: _error_handler
File: /var/www/html/application/controllers/Detail.php
Line: 574
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 488
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Objectives Assessment of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection prevalence and immunity is cornerstones in the fight against COVID-19 pandemic. For pandemic control, reliable assays for the detection of anti-SARS-CoV-2 antibodies are required. This pilot external quality assessment (EQA) scheme aimed to independently assess the participants' clinical performance of anti-SARS-CoV-2 testing, to identify shortcomings in clinical practice and to evaluate the suitability of the scheme format. Methods The EQA scheme consisted of eight serum samples with variable reactivity against SARS-CoV-2 intended for the analysis of anti-SARS-CoV-2 immunoglobulin (Ig)G, IgA, and IgM antibodies. Laboratories reported: (1) results for each sample and the respective method, (2) raw data from replicate testing of each sample. Results The 16 selected pilot EQA participants reported 294 interpreted results and 796 raw data results from replicate testing. The overall error rate for the anti-SARS-CoV-2 IgG, IgA, and IgM tests was 2.7, 6.9, and 16.7%, respectively. While the overall diagnostic specificity was rated as very high, sensitivity rates between 67 and 98% indicate considerable quality differences between the manufacturers, especially for IgA and IgM. Conclusions Even the results reported by the small number of participants indicate a very heterogeneous landscape of anti-SARS-CoV-2 serological testing. Differences of available tests and the individual performance of laboratories result in a success rate of 57.1% with one laboratory succeeding for all three antibody-classes. These results are an incentive for laboratories to participate in upcoming open EQA schemes that are needed to achieve a harmonization of test results and to improve serological testing.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1515/cclm-2020-1183 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!