Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: Few studies exist that examined the role of radiofrequency microneedling (RFMN) in skin electrocoagulation. This research utilized a porcine model to understand bipolar dermal delivery from an RFMN device.
Aims: The objective of this study was to elucidate and compare the dermal thermal effects of a RFMN device producing 1 and 2 MHz signal amplitudes, with respective voltage and current gradients, utilizing noninsulated and insulated needles by examining the histologic effects on porcine skin.
Methods: Two separate animal studies were conducted to evaluate the electrocoagulation and thermal diffusion effects using the RFMN device. The electrocoagulation effects were assessed histologically using hematoxylin and eosin (H&E) staining, and heating effects were assessed through thermal imaging.
Results: Histology results of the thermal injury induced by insulated needles demonstrated that 2 MHz resulted in a narrow and concentrated coagulation zone as compared to 1 MHz. Further, the 1 MHz insulated needle resulted in ovular shaped tissue coagulation as compared to 2 MHz tissue coagulation that was columnar. Finally, full thermal diffusion occurs seconds after the set RF conduction time.
Conclusion: The findings showed that 1 MHz insulated needle produces larger coagulations with an increase in power level, the 1 MHz noninsulated array was comparable to the 2 MHz insulated array with similar histologic features, and heat dissipates seconds after the set conduction time.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8048620 | PMC |
http://dx.doi.org/10.1111/jocd.13690 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!