Purpose: Real-time monitoring of physiological changes of tumor tissue during radiation therapy (RT) could improve therapeutic efficacy and predict therapeutic outcomes. Cherenkov radiation is a normal byproduct of radiation deposited in tissue. Previous studies in rat tumors have confirmed a correlation between Cherenkov emission spectra and optical measurements of blood-oxygen saturation based on the tissue absorption coefficients. The purpose of this study is to determine if it is feasible to image Cherenkov emissions during radiation therapy in larger human-sized tumors of pet dogs with cancer. We also wished to validate the prior work in rats, to determine if Cherenkov emissions have the potential to act an indicator of blood-oxygen saturation or water-content changes in the tumor tissue-both of which have been correlated with patient prognosis.

Methods: A DoseOptics camera, built to image the low-intensity emission of Cherenkov radiation, was used to measure Cherenkov intensities in a cohort of cancer-bearing pet dogs during clinical irradiation. Tumor type and location varied, as did the radiation fractionation scheme and beam arrangement, each planned according to institutional standard-of-care. Unmodulated radiation was delivered using multiple 6 MV X-ray beams from a clinical linear accelerator. Each dog was treated with a minimum of 16 Gy total, in ≥3 fractions. Each fraction was split into at least three subfractions per gantry angle. During each subfraction, Cherenkov emissions were imaged.

Results: We documented significant intra-subfraction differences between the Cherenkov intensities for normal tissue, whole-tumor tissue, tissue at the edge of the tumor and tissue at the center of the tumor (p<0.05). Additionally, intra-subfraction changes suggest that Cherenkov emissions may have captured fluctuating absorption properties within the tumor.

Conclusion: Here we demonstrate that it is possible to obtain Cherenkov emissions from canine cancers within a fraction of radiotherapy. The entire optical spectrum was obtained which includes the window for imaging changes in water and hemoglobin saturation. This lends credence to the goal of using this method during radiotherapy in human patients and client-owned pets.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7449466PMC
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0238106PLOS

Publication Analysis

Top Keywords

cherenkov emissions
16
radiation therapy
12
cherenkov
9
radiation
8
changes tumor
8
tumor tissue
8
cherenkov radiation
8
blood-oxygen saturation
8
pet dogs
8
cherenkov intensities
8

Similar Publications

Novel high-stopping power scintillators for medical applications.

Proc SPIE Int Soc Opt Eng

February 2024

Radiation Monitoring Devices, Inc., 44 Hunt St., Watertown, MA, USA 02472- 4624.

Development of new scintillator materials is a continuous effort, which recently has been focused on materials with higher stopping power. Higher stopping power can be achieved if the compositions include elements such as Tl (Z=81) or Lu (Z=71), as the compounds gain higher densities and effective atomic numbers. In context of medical imaging this translates into high detection efficiency (count rates), therefore, better image quality (statistics, thinner films) or lower irradiation doses to patients in addition to lowering of cost.

View Article and Find Full Text PDF

Optimized scintillation imaging in low dose rate and bright room light conditions.

Biomed Phys Eng Express

November 2024

Department of Medical Physics, School of Medicine and Public Health, University of Wisconsin-Madison, WI, United States of America.

. To develop a robust method for non-contact surface dosimetry during Total Body Irradiation (TBI) that uses an optimally paired choice of scintillator material with camera photocathode and can work insensitively to the normal ambient room lighting conditions (∼500 Lux)..

View Article and Find Full Text PDF

Positron emission tomography (PET) is the most sensitive biomedical imaging modality for non-invasively detecting and visualizing positron-emitting radiopharmaceuticals within a subject. In PET, measuring the time-of-flight (TOF) information for each pair of 511-keV annihilation photons improves effective sensitivity but requires high timing resolution. Hybrid materials that emit both scintillation and Cherenkov photons, such as bismuth germanate (BGO), recently offer the potential for more precise timing information from Cherenkov photons while maintaining adequate energy resolution from scintillation photons.

View Article and Find Full Text PDF

Trends in cancer imaging.

Trends Cancer

November 2024

Department of Nuclear Medicine, Institute of Clinical Nuclear Medicine, Renji Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai 200127, China. Electronic address:

Molecular imaging of cancer is a collaborative endeavor, uniting scientists and physicians from diverse fields. Such collaboration is actively developing and translating cutting-edge molecular imaging approaches to enhance the diagnostic landscape of human malignancies. The advent of positron emission tomography (PET) and PET imaging tracers has realized non-invasive target annotation and tumor characterization at the molecular level.

View Article and Find Full Text PDF