Background: The alpha angle is the most often used measure to classify cam morphology. There is currently no agreement on which alpha angle threshold value to use.
Purpose: To systematically investigate the different alpha angle threshold values used for defining cam morphology in studies aiming to identify this threshold and to determine whether data are consistent enough to suggest an alpha angle threshold to classify cam morphology.
Study Design: Systematic review; Level of evidence, 3.
Methods: The Embase, Medline (Ovid), Web of Science, Cochrane Central, and Google Scholar databases were searched from database inception to February 28, 2019. Studies aiming at identifying an alpha angle threshold to classify cam morphology were eligible for inclusion.
Results: We included 4 case-control studies, 10 cohort studies, and 1 finite-element study from 2437 identified publications. Studies (n = 3) using receiver operating characteristic (ROC) curve analysis to distinguish asymptomatic people from patients with femoroacetabular impingement syndrome consistently observed alpha angle thresholds between 57° and 60°. A 60° threshold was also found to best discriminate between hips with and without cam morphology in a large cohort study based on a bimodal distribution of the alpha angle. Studies (n = 8) using the upper limit of the 95% reference interval as threshold proposed a wide overall threshold range between 58° and 93°. When stratified by sex, thresholds between 63° and 93° in male patients and between 58° and 94° in female patients were reported.
Conclusion: Based on the available evidence, mostly based on studies using ROC curve analysis, an alpha angle threshold of ≥60° is currently the most appropriate to classify cam morphology. Further research is required to fully validate this threshold.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7418265 | PMC |
http://dx.doi.org/10.1177/2325967120938312 | DOI Listing |
Anal Chem
January 2025
School of Optoelectronic Engineering and Instrumentation Science, Dalian University of Technology, Dalian, Liaoning 116024, China.
A linear spot-type multipass cell-enhanced fiber-optic photoacoustic gas microprobe is proposed. To further reduce the volume of the gas chamber and enhance the photoacoustic signal, we designed the cross section of the photoacoustic tube as a slit with a height of 10 mm and a width of 1.5 mm.
View Article and Find Full Text PDFClin Orthop Relat Res
December 2024
Naval Medical Center San Diego, San Diego, CA, USA.
Background: Femoroacetabular impingement (FAI) is a well-recognized cause of hip pain in adults. The hip-spine relationship between the femur, pelvis, and lumbosacral spine has garnered recent attention in hip arthroplasty. However, the hip-spine relationship has not been well described in patients with FAI.
View Article and Find Full Text PDFImmun Inflamm Dis
January 2025
School of Basic Medical Sciences, Cheeloo College of Medicine, Shandong University, Jinan, Shandong, People's Republic of China.
Background: Traumatic spinal cord injury (SCI) is an incurable condition that is the largest cause of disability. In previous studies, Isosteviol sodium (STVNa) has been shown to protect rats against acute focal cerebral ischemia; however, the effects of STVNa on SCI recovery in rats remain unknown.
Methods: STVNa was given intraperitoneally after SCI to see if it had any neuroprotective benefits.
J Avian Med Surg
January 2025
Department of Veterinary Clinical Sciences, School of Veterinary Medicine, Louisiana State University, Baton Rouge, LA 70803, USA.
Viscoelastic testing evaluates the formation and lysis of a clot over time, allowing more complete assessment of patient hemostasis in real time, whereas traditional tests, such as prothrombin time and partial thromboplastin time, only measure coagulation factor function. Patient-side viscoelastic coagulation monitors are easy to use, portable, and provide faster turnaround time than commercial laboratories. Viscoelastic testing requires only 0.
View Article and Find Full Text PDFMaterials (Basel)
December 2024
School of Materials Science and Engineering, North University of China, Taiyuan 030051, China.
In this paper, in order to investigate the harmonious relationship between the compression deformation behavior of metastable β titanium alloy and the microstructure evolution, the β solution-treated Ti-10V-2Fe-3Al (Ti-1023) alloy was compressed at room temperature and its deformation behavior was analyzed. Optical microscopy (OM) and field emission electron microscopy (FESEM) were used to study the microstructure evolution of alloys at different strain rates. The results show that the stress-induced martensite transformation (SIMT) is more easily activated by low strain rate compression deformation, which is conducive to improving its comprehensive mechanical properties.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!