Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
The bending fracture behaviors of long bone have gained great attention due to the high bending fracture risk during sports events, traffic accidents, and falling incidents, etc. For evaluating bone bending behaviors, most of the previous studies used an indenter in three point bending experiments while the effect of its rigidity was never considered. In this work, using the porcine long bones, the three point bending tests were conducted to explore the bone fracture behaviors under a rigid indenter. In addition to collecting the force applied, the bone fracture dynamic process was recorded by high-speed photography, and the fracture surface profile in mesoscale was observed by the scanning electron microscope (SEM). Based on CT scanning of long bones, the cross section properties of test specimens were calculated by a homemade matlab script for correlating with their failure strengths. Also, a subject-specific finite element (FE) model was developed to identify the outcomes induced by a rigid indenter on simulation. Findings led to conclusions as follows: (1) The tension fracture came with fracture path deflection, which was caused by the bone indentation induced mesoscale crack-opening. Due to this damage before the whole bone fracture, a bone fracture moment correction was established to compensate experimental data. (2) The plastic indentation caused the force fluctuation as suggested by correlation analysis. (3) The bone failure moment correlated with the inertial moment of the bone cross section at the fracture location higher than the traditional cross section area. (4) In the subject-specific simulation, the indentation caused compression fracture under a much lower failure force. Removing the element erosion on the indenter-contacted area only during the validation was verified as a good option to solve this issue.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1115/1.4048203 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!