Objectives: This study evaluates aerosol production with high-flow nasal cannula (HFNC) and noninvasive positive pressure ventilation (NIPPV) compared to 6 L/min by low-flow nasal cannula.

Methods: Two healthy volunteers were randomized to control (6 L/min by low-flow nasal cannula), NIPPV, or HFNC using block randomization. NIPPV conditions were studied using continuous positive airway pressures of 5, 10, and 15 cm HO with an FiO of 1.0 delivered via full-face mask. HFNC conditions included flow rates of 30 and 40 L/min with an FiO of 1.0 with and without coughing. HFNC and low-flow nasal cannula conditions were repeated with and without participants wearing a surgical mask. Six aerosol sizes (0.3, 1.0, 2.5, 5, and 10 µm) and total aerosol mass were measured at 2 and 6 ft from the participant's nasopharynx.

Results: There was no significant difference in aerosol production between either HFNC or NIPPV and control. There was also no significant difference with the use of a procedural mask over the HFNC. There was significant variation between the 2 participants, but in neither case was there a difference compared to control. There was an aerosol-time trend, but there does not appear to be a difference between either flow rate, pressure, or control. Furthermore, there was no accumulation of total aerosol particles over the total duration of the experiment in both HFNC and NIPPV conditions.

Conclusions: HFNC and NIPPV did not increase aerosol production compared to 6 L/min by low-flow nasal cannula in this experiment involving healthy volunteers.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7280651PMC
http://dx.doi.org/10.1002/emp2.12152DOI Listing

Publication Analysis

Top Keywords

nasal cannula
16
low-flow nasal
16
aerosol production
12
6 l/min low-flow
12
hfnc nippv
12
hfnc
8
compared 6 l/min
8
healthy volunteers
8
mask hfnc
8
total aerosol
8

Similar Publications

Transcatheter Aspiration of Tricuspid Vegetation.

JACC Case Rep

December 2024

Jesselson Integrated Heart Center, The Eisenberg R&D Authority, Shaare Zedek Medical Center, Faculty of Medicine, The Hebrew University of Jerusalem, Jerusalem, Israel.

Objective: This study sought to present the endovascular approach of transcatheter aspiration using the FlowTriever (Inari Medical) aspiration system for high surgical risk patients with right-sided infective endocarditis.

Key Steps: General anesthesia and transesophageal echocardiogram guidance; ultrasonography-guided femoral vein access, preclosure sutures, and insertion of a 24-F sheath; insertion of straight 24-F aspiration cannula over a stiff wire, parked in the superior vena cava; introduction of a 20-F curved cannula inside the 24-F cannula to create a telescopic assembly; accurate positioning using the right ventricle inflow/outflow projection in biplane mode; adjustment of the curved cannula radius by sliding the inner cannula in and out inside the mother cannula; manual aspiration of the vegetation; Postaspiration transesophageal echocardiogram assessment.

Potential Pitfalls: Avoid leaflet and annular injury and account for potential embolization.

View Article and Find Full Text PDF

An 85-year-old woman with atrial fibrillation was found to have a large 4.5- × 3.5-cm left atrial mass.

View Article and Find Full Text PDF

Subcutaneous emphysema is a well-known complication of chest tube insertion that can become life-threatening. Severe cases often progress rapidly, necessitating prompt intervention to prevent complications such as airway obstruction and respiratory failure. We report the case of a 57-year-old man who developed extensive subcutaneous emphysema following chest tube insertion.

View Article and Find Full Text PDF

Background: During the COVID-19 pandemic, managing respiratory failure in critically ill patients has presented significant challenges. A high-flow nasal cannula (HFNC) has been established as an effective respiratory support modality, offering heated, humidified oxygen at high flow rates. However, concerns persist regarding the potential for aerosol dispersion and the risk of viral transmission, particularly in COVID-19.

View Article and Find Full Text PDF

Background: Acute bronchiolitis (AB) is the most common lower respiratory tract infection in infants. Clinician diagnosis and management vary due to limited objective assessment tools. Point-of-care lung ultrasound (LUS) offers a promising diagnostic and prognostic tool in the emergency department (ED), however, the time to perform LUS is of concern in the emergency setting.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!