The idea of decoupling "environmental bads" from "economic goods" has been proposed as a path towards sustainability by organizations such as the OECD and UN. Scientific consensus reports on environmental impacts (e.g., greenhouse gas emissions) and resource use give an indication of the kind of decoupling needed for ecological sustainability: global, absolute, fast-enough and long-enough. This goal gives grounds for a categorisation of the different kinds of decoupling, with regard to their relevance. We conducted a survey of recent (1990-2019) research on decoupling on Web of Science and reviewed the results in the research according to the categorisation. The reviewed 179 articles contain evidence of absolute impact decoupling, especially between CO2 (and SOX) emissions and evidence on geographically limited (national level) cases of absolute decoupling of land and blue water use from GDP, but not of economy-wide resource decoupling, neither on national nor international scales. Evidence of the needed absolute global fast-enough decoupling is missing.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7330600PMC
http://dx.doi.org/10.1016/j.envsci.2020.06.016DOI Listing

Publication Analysis

Top Keywords

decoupling
9
ecological sustainability
8
decoupling ecological
4
sustainability categorisation
4
categorisation review
4
review literature
4
literature idea
4
idea decoupling
4
decoupling "environmental
4
"environmental bads"
4

Similar Publications

Rapid Acquisition of High-Pixel Fluorescence Lifetime Images of Living Cells via Image Reconstruction Based on Edge-Preserving Interpolation.

Biosensors (Basel)

January 2025

State Key Laboratory of Radio Frequency Heterogeneous Integration (Shenzhen University), Key Laboratory of Optoelectronic Devices and Systems of Ministry of Education and Guangdong Province, College of Physics and Optoelectronic Engineering, Shenzhen University, Shenzhen 518060, China.

Fluorescence lifetime imaging (FLIM) has established itself as a pivotal tool for investigating biological processes within living cells. However, the extensive imaging duration necessary to accumulate sufficient photons for accurate fluorescence lifetime calculations poses a significant obstacle to achieving high-resolution monitoring of cellular dynamics. In this study, we introduce an image reconstruction method based on the edge-preserving interpolation method (EPIM), which transforms rapidly acquired low-resolution FLIM data into high-pixel images, thereby eliminating the need for extended acquisition times.

View Article and Find Full Text PDF

Optical Coherence Tomography (OCT) is a crucial imaging modality for diagnosing and monitoring retinal diseases. However, the accurate segmentation of fluid regions and lesions remains challenging due to noise, low contrast, and blurred edges in OCT images. Although feature modeling with wide or global receptive fields offers a feasible solution, it typically leads to significant computational overhead.

View Article and Find Full Text PDF

Magnetic field probe-based co-simulation method for irregular volume-type inductively coupled wireless MRI radiofrequency coils.

Magn Reson Imaging

January 2025

Vanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, TN 37232, USA; Department of Radiology and Radiological Sciences, Vanderbilt University Medical Center, Nashville, TN 37232, USA; Department of Electrical and Computer Engineering, Vanderbilt University, Nashville, TN 37232, USA. Electronic address:

Background: Inductively coupled wireless coils are increasingly used in MRI due to their cost-effectiveness and simplicity, eliminating the need for expensive components like preamplifiers, baluns, coil plugs, and coil ID circuits. Existing tools for predicting component values and electromagnetic (EM) fields are primarily designed for cylindrical volume coils, making them inadequate for irregular volume-type wireless coils.

Purpose: The aim of this study is to introduce and validate a novel magnetic (H-) field probe-based co-simulation method to accurately predict capacitance values and EM fields for irregular volume-type wireless coils, thereby addressing the limitations of current prediction tools.

View Article and Find Full Text PDF

In an axion haloscope, the weak photon signal, theoretically converted from axions, is captured by a detection cavity. The signal from the cavity is too weak to be acquired by a signal receiver. The amplification chain assists the signal acquisition by amplifying the signal and requires accurate gain calibration.

View Article and Find Full Text PDF

Imaginal exposure is a standard procedure of cognitive behavioral therapy for the treatment of anxiety and panic disorders. It is often used when in vivo exposure is not possible, too stressful for patients, or would be too expensive. The Bio-Informational Theory implies that imaginal exposure is effective because of the perceptual proximity of mental imagery to real events, whereas empirical findings suggest that propositional thought of fear stimuli (i.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!