AI Article Synopsis

Article Abstract

The outbreak of COVID-19, and its current resurgence in the United States has resulted in a shortage of isolation rooms within many U.S. hospitals admitting COVID-19-positive cases. As a result, hospital systems, especially those at an epicenter of this outbreak, have initiated task forces to identify and implement various approaches to increase their isolation capacities. This paper describes an innovative temporary anteroom in addition to a portable air purifier unit to turn a general patient room into an isolation space. Using an aerosolization system with a surrogate oil-based substance, we evaluated the effectiveness of the temporary plastic anteroom and the portable air purifier unit. Moreover, the optimal location of the portable unit, as well as the effect of negative pressurization and door opening on the containment of surrogate aerosols were assessed. Results suggested that the temporary anteroom alone could prevent the migration of nearly 98% of the surrogate aerosols into the adjacent corridor. Also, it was shown that the best location of a single portable air purifier unit is inside the isolation room and near the patient's bed. The outcome of this paper can be widely used by hospital facilities managers when attempting to retrofit a general patient room into an airborne infection isolation room.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7424318PMC
http://dx.doi.org/10.1016/j.buildenv.2020.107186DOI Listing

Publication Analysis

Top Keywords

portable air
12
air purifier
12
purifier unit
12
temporary plastic
8
temporary anteroom
8
general patient
8
patient room
8
surrogate aerosols
8
isolation room
8
portable
5

Similar Publications

NEMS generated electromechanical frequency combs.

Microsyst Nanoeng

January 2025

Department of Systems Design Engineering, University of Waterloo, Waterloo, ON, N2L 3G1, Canada.

This paper presents a novel technique for low-power generation of frequency combs (FC) over a wide frequency range. It leverages modal interactions between electrical and mechanical resonators in electrostatic NEMS operating in air to provide a simple architecture for FC generators. A biased voltage signal drives the electrical resonator at resonance which is set to match an integer submultiple of twice the mechanical resonator's resonance.

View Article and Find Full Text PDF

Moisture-Electric Generators Working in Subzero Environments Based on Laser-Engraved Hygroscopic Hydrogel Arrays.

ACS Nano

January 2025

State Key Laboratory of Luminescence and Applications, Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun 130033, People's Republic of China.

Moisture-electric generators (MEGs) generate power by adsorbing water from the air. However, their performance at low temperatures is hindered due to icing. In the present work, MEG arrays are developed by laser engraving techniques and a modulated low-temperature hydrogel as the absorbent material.

View Article and Find Full Text PDF

Recent developments on aerial lab-on-a-drone platforms for remote environmental monitoring: A review.

Anal Chim Acta

February 2025

Instituto de Química, Universidade Federal de Goiás, 74690-900, Goiânia, GO, Brazil; Instituto Nacional de Ciência e Tecnologia de Bioanalítica, Campinas, 13084-971, SP, Brazil. Electronic address:

Background: Distinct classes of environmental contaminants - such as microplastics, volatile organic compounds, inorganic gases, hormones, pesticides/herbicides, and heavy metals - have been continuously released into the environment from different sources. Anthropogenic activities with unprecedented consequences have impacted soil, surface waters, and the atmosphere. In this scenario, developing sensing materials and analytical platforms for monitoring water and air quality is essential to supporting worldwide environmental control agencies.

View Article and Find Full Text PDF

Classroom air quality in a randomized crossover trial with portable HEPA air cleaners.

J Expo Sci Environ Epidemiol

January 2025

Department of Environmental and Occupational Health, Joe C. Wen School of Population & Public Health, University of California, Irvine, CA, USA.

Background: Children living in communities with lower socioeconomic status and higher minority populations are often disproportionately exposed to particulate matter (PM) compared to children living in other communities.

Objective: We assessed whether adding HEPA filter air cleaners to classrooms with existing HVAC systems reduces indoor air pollution exposure.

Methods: From July 2022 to June 2023, using a block randomized crossover trial of 17 Los Angeles Unified School District elementary schools, classroom PM concentrations were monitored and compared for 99 classrooms with HEPA filter air cleaners and 87 classrooms with non-HEPA filter air cleaners.

View Article and Find Full Text PDF

Ecosystems and environments are impacted by atmospheric pollution, which has significant effects on human health and climate. For these reasons, devices for developing portable and low-cost monitoring systems are required to assess human exposure during daily life. In the last decade, the advancements of 3D printing technology have pushed researchers to exploit, in different fields of applications, the advantages offered, such as rapid prototyping and low-cost replication of complex sample treatment devices.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!