A Comparison Between Refraction From an Adaptive Optics Visual Simulator and Clinical Refractions.

Transl Vis Sci Technol

Vision and Eye Research Institute, School of Medicine, Anglia Ruskin University, Cambridge, UK.

Published: June 2020

Purpose: The Visual Adaptive Optics (VAO) is an adaptive optics visual simulator with an embedded Hartmann-Shack aberrometer that can give objective and subjective refraction measures. The aim of the present study was to compare the findings of the objective and subjective refractions from the VAO with a commercial autorefractometer (Topcon Corp., Tokyo, Japan) and a subjective refraction by an optometrist. The influence of age, refractive error type, and presence of ocular diseases was ascertained.

Methods: The refractive error was obtained in 469 participants using the four techniques mentioned. Data were analyzed with power vectors mean spherical equivalent, the vertical Jackson-Cross-Cylinder, and the oblique Jackson-Cross-Cylinder. Age, refractive error type (myopia, emmetropia, hyperopia) and presence of ocular diseases (yes, no) were included as covariates. Agreement was assessed using the 95% interval of agreement.

Results: The median spherical equivalent difference and the interval of agreement for all the participants with the VAO subjective, VAO objective, and autorefraction with the clinical subjective refraction were (+0.13, 1.80 diopters [D]), (+0.38, 1.80 D), and (-0.38, 2.10 D), respectively. When considering only healthy participants, the results were (+0.06, 1.70 D), (+0.38, 1.60 D) and (-0.25, 1.80 D), respectively. When considering only those participants with any ocular condition, the results with VAO subjective, VAO objective and autorefraction were (+0.13, 2.50 D), (+0.31, 2.70 D), and (-0.50, 4.80 D), respectively.

Conclusions: The VAO subjective refraction is more accurate than VAO objective refraction and autorefraction, regardless of refractive error, age, or the presence of ocular conditions. The presence of ocular conditions significantly deteriorates the accuracy of all refraction methods.

Translational Relevance: Reported clinical comparisons between different types of standard refraction methods and a new adaptive optics refraction instrument (VAO) are in good agreement and support the further development of this method to increase refraction accuracy and to refract quicker than standard procedures.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7414619PMC
http://dx.doi.org/10.1167/tvst.9.7.23DOI Listing

Publication Analysis

Top Keywords

adaptive optics
16
subjective refraction
16
refractive error
16
presence ocular
16
vao subjective
12
vao objective
12
vao
9
refraction
9
optics visual
8
visual simulator
8

Similar Publications

This study explores the optoelectronic and photovoltaic potential of acceptor-π-donor (A-π-D) architectures utilizing CSi quantum dots (CSiQDs) through a combination of density functional theory (DFT) and time-dependent DFT (TDDFT). We examined two key structural configurations: C-C and Si-C conformers. In these systems, CSiQDs serve as the acceptor, CHSF as the π-bridge, and 3 × (CHO) as the donor.

View Article and Find Full Text PDF

Rapid validation of newly predicted materials through autonomous synthesis requires real-time adaptive control methods that exploit physics knowledge, a capability that is lacking in most systems. Here, we demonstrate an approach to enable real-time control of thin film synthesis by combining optical diagnostics with a Bayesian state estimation method. We developed a physical model for film growth and applied the direct filter (DF) method for real-time estimation of nucleation and growth rates during pulsed laser deposition (PLD).

View Article and Find Full Text PDF

Introduction: The innate immune response is an important first checkpoint in the evolution of an infection. Although adaptive immunity is generally considered the immune component that retains antigenic memory, innate immune responses can also be affected by previous stimulations. This study evaluated the impact of vaccination on innate cell activation by TLR7/8 agonist R848, as well as seasonal variations.

View Article and Find Full Text PDF

Across two experiments, we implemented a novel gaze-contingent eye-tracking paradigm to investigate the early emergence of memory benefits from active control over exploration and to examine how exploratory behaviours affect memory formation in early development. Toddlers (experiment 1: = 36, 18-36 months; experiment 2: = 41, 23-36 months) were either allowed to actively control their exploration (active condition) or presented with the same information that they could only passively observe (passive condition in experiment 1; yoked condition in experiment 2). They were then tested in a preferential-looking paradigm in which familiar versus novel stimuli were presented in pairs.

View Article and Find Full Text PDF

Adaptive mode-selective multiplexers offer the potential to control the modal content within multimode fibers for space division multiplexing (SDM). To such an end, spatial light modulators allow programmable control over the phase, amplitude, and polarization of optical wavefronts. One of the major challenges is to precisely match the manipulated beam to the waveguide modes in the multimode fiber.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!