Image quality assessment of a photon counting detector in x-ray projection imaging.

Nucl Instrum Methods Phys Res A

Advanced Medical Imaging Center and School of Electrical and Computer Engineering, University of Oklahoma, Norman, OK 73019, USA.

Published: September 2019

The recent advancements in the photon counting detection have created a significant growing research interest in the x-ray imaging. It is essential to objectively understand the image quality parameters of a photon counting detector before developing imaging applications. In this work, we have assessed the imaging quality of a cadmium telluride (CdTe) based PCD in projection imaging mode. The detector is 70.4 mm × 6.6 mm dimensions. The detector has a pixel array of 64×4 with a pixel pitch of 1.1 mm×1.65 mm. With each pixel having 4 channels in its corresponding ASIC, this PCD can create three bin images from a single projection. With a microfocus x-ray source, the imaging quality in each bin image was measured in terms of the spatial resolution, noise, and contrast to noise ratio (CNR). We used 70 kV, 50μA, 10 s (0.5mAs) with 0.5mm thick aluminum (Al) filter for the acquisition of each image. The MTF curves indicated that the spatial resolution for the bin-1, bin-2, and bin-3 was almost identical. The NNPS curves indicated that the noise in bin 1 and bin 2 images was almost the same for all frequencies while bin 3 image had relatively less noise. The CNR analyses showed that the bin-1 image had the highest CNR. As the flux was increased from 0.5 to 1 mAs, the number of detected counts also increased that resulted in the CNR increase. Beyond this flux, the pulse pileup occurred due to which multiple counts were read as single that resulted in few detected counts and lower CNR. The knowledge of the spatial resolution, noise, and CNR in terms of energy binning allows the determination and optimization of imaging techniques necessary for various applications.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7440679PMC
http://dx.doi.org/10.1016/j.nima.2019.05.054DOI Listing

Publication Analysis

Top Keywords

photon counting
12
spatial resolution
12
image quality
8
counting detector
8
projection imaging
8
imaging quality
8
bin images
8
bin image
8
resolution noise
8
curves indicated
8

Similar Publications

Imaging of Acute Pulmonary Embolism: An Update.

Radiol Clin North Am

March 2025

Department of Radiology, University of Texas Southwestern Medical Center, Dallas, TX 75390, USA; Department of Internal Medicine, University of Texas Southwestern Medical Center, Dallas, TX 75390, USA.

Imaging is essential in the evaluation and management of acute pulmonary embolism. Advances in multi-energy CT including dual-energy CT and photon-counting CT have allowed faster scans with lower radiation dose and optimal quality. Artificial intelligence has a potential role in triaging potentially positive examinations and could serve as a second reader.

View Article and Find Full Text PDF

: Diffuse myocardial fibrosis and altered deformation are relevant prognostic factors in aortic stenosis (AS) patients. The aim of this exploratory study was to investigate the relationship between myocardial strain, and myocardial extracellular volume (ECV) in patients with severe AS with a photon-counting detector (PCD)-CT. : We retrospectively included 77 patients with severe AS undergoing PCD-CT imaging for transcatheter aortic valve replacement (TAVR) planning between January 2022 and May 2024 with a protocol including a non-contrast cardiac scan, an ECG-gated helical coronary CT angiography (CCTA), and a cardiac late enhancement scan.

View Article and Find Full Text PDF

A major histologic feature of cirrhosis is the loss of liver architecture with collapse of tissue and vascular changes per unit. We developed qVessel to quantify the arterial density (AD) in liver biopsies with chronic disease of varied etiology and stage. 46 needle liver biopsy samples with chronic hepatitis B (CHB), 48 with primary biliary cholangitis (PBC) and 43 with metabolic dysfunction-associated steatotic liver disease (MASLD) were collected at the Shuguang Hospital.

View Article and Find Full Text PDF

Given their molecular properties and electronic structure, graphyne and graphdiyne are promising materials with numerous applications in different fields of material science. Dehydrobenzoannules (DBAs) are candidates that can serve as building blocks for synthesizing and designing new 2D carbon allotropes; however, only a few graphynes have been produced on a practical scale. Herein, we present our investigation of three DBAs, which serve as a model to understand the relationship between the structure and property, contributing to 2D carbon allotropes' rational design and synthetic effort.

View Article and Find Full Text PDF

In recent years, the wine industry has been researching how to improve wine quality along the production value chain. In this scenario, we present here a new tool, MicroVi, a cost-effective chip-sized microscopy solution to detect and count yeast cells in wine samples. We demonstrate that this novel microscopy setup is able to measure the same type of samples as an optical microscopy system, but with smaller size equipment and with automated cell count configuration.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!