Shear Wave Elastography of the Maternal Cervix: A Comparison of Transvaginal and Transabdominal Ultrasound Approaches.

J Ultrasound Med

Discipline of Medical Radiation Sciences, School of Molecular and Life Sciences, Curtin University, Perth, Western Australia, Australia.

Published: April 2021

Objectives: This work aimed to compare the use of shear wave elastography on the maternal cervix with transvaginal (TV) and transabdominal (TA) ultrasound approaches to assess differences in shear wave speeds (SWSs) obtained for possible clinical use.

Methods: In both TV and TA ultrasound approaches, SWS measurements were attempted at the anterior and posterior portions of the internal and external cervical os on 38 gravid participants.

Results: A larger number of SWS measurements were obtained at the anterior portion of the cervix by both approaches. The numbers of reliable measurements of the SWS obtained at the anterior and posterior portions of the internal and external os were 99, 65, 103, and 77 in the TA approach and 93, 53, 110, and 87 in the TV approach, respectively. The mean difference in -the SWS obtained between the TV and TA ultrasound approaches was statistically significant at the anterior and posterior portions of the internal os, with differences of 0.67 and 0.52 m/s (P < .05). Differences were not significant at the external os both anteriorly and posteriorly, with differences of 0.15 and - 0.07 m/s (P > .05).

Conclusions: Both TA and TV ultrasound approaches may be used to obtain SWSs in the maternal cervix. This study has shown that SWSs obtained by each approach need to be considered independently, as the TV approach produced significantly greater SWSs at the internal os compared to the TA approach, but the values were similar at the external os.

Download full-text PDF

Source
http://dx.doi.org/10.1002/jum.15440DOI Listing

Publication Analysis

Top Keywords

ultrasound approaches
20
shear wave
12
maternal cervix
12
anterior posterior
12
posterior portions
12
portions internal
12
wave elastography
8
elastography maternal
8
transvaginal transabdominal
8
transabdominal ultrasound
8

Similar Publications

Choledochal cyst or biliary tract cyst is a pathological condition characterized by abnormal dilation of the hepatobiliary system. In veterinary medicine, case descriptions and histological characterizations of this biliary malformation are scarce, requiring reliance on data from human medicine. A presumptive diagnosis typically involves imaging studies, with histopathological examination required for confirmation.

View Article and Find Full Text PDF

Since the adoption of neoadjuvant chemoradiation and total mesorectal excision as the standard in rectal cancer care, there has been marked improvement in the local recurrence rates. In this context, restaging magnetic resonance imaging (MRI) plays a key role in the assessment of tumor response, occasionally enabling organ-sparing approaches. However, the role of restaging MRI in evaluating lateral lymph nodes remains limited.

View Article and Find Full Text PDF

Purpose Of Review: This review evaluates recent advancements in Technetium-99 m pyrophosphate (99mTc-PYP) imaging for transthyretin amyloid cardiomyopathy (ATTR-CM). We summarize the advantages of single-photon emission computed tomography (SPECT) over planar imaging, the potential impact of quantitative methods, and emerging data for quantifying response to therapy.

Recent Findings: The current literature demonstrates the superior diagnostic accuracy of SPECT compared with planar imaging in 99mTc-PYP studies.

View Article and Find Full Text PDF

Adaptive ensemble loss and multi-scale attention in breast ultrasound segmentation with UMA-Net.

Med Biol Eng Comput

January 2025

Artificial Intelligence Lab, School of Computer and Information Sciences, University of Hyderabad, Hyderabad, 500046, India.

The generalization of deep learning (DL) models is critical for accurate lesion segmentation in breast ultrasound (BUS) images. Traditional DL models often struggle to generalize well due to the high frequency and scale variations inherent in BUS images. Moreover, conventional loss functions used in these models frequently result in imbalanced optimization, either prioritizing region overlap or boundary accuracy, which leads to suboptimal segmentation performance.

View Article and Find Full Text PDF

Background: Invasive systems are commonly used for monitoring intracranial pressure (ICP) in traumatic brain injury (TBI) and are considered the gold standard. The availability of invasive ICP monitoring is heterogeneous, and in low- and middle-income settings, these systems are not routinely employed due to high cost or limited accessibility. The aim of this consensus was to develop recommendations to guide monitoring and ICP-driven therapies in TBI using non-invasive ICP (nICP) systems.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!