A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Intradialytic isometric handgrip exercise does not cause hemodynamic instability: A randomized, cross-over, pilot study. | LitMetric

Hemodialysis (HD) patients experience hemodynamic instability and intradialytic exercise seems to attenuate it. This study aimed to verify the acute hemodynamic response to different intradialytic handgrip exercise intensities in HD patients. In a randomized, cross-over, experimental pilot study, eight patients completed two experimental sessions and one control in random order: (a) regular HD; (b) low-intensity isometric handgrip exercise; and (c) moderate-intensity isometric handgrip exercise. BP and heart rate variability were recorded immediately before and every 15 minutes. Isometric handgrip exercise protocols, regardless of the intensity, did not lead to significant changes in hemodynamic stability, nor when compared to the control condition (P > .05). The systolic BP and double product significantly increased immediately after the moderate-intensity protocol (122.0 ± 15.9 vs 131.3 ± 19.8, P < .05; 9094.7 ± 1705.7 vs 9783.0 ± 1947.9, P < .05, respectively) but returned to the pre-exercise values 10 minutes later. We conclude that intradialytic isometric handgrip exercise does not induce hemodynamic instability at low and moderate intensities.

Download full-text PDF

Source
http://dx.doi.org/10.1111/1744-9987.13581DOI Listing

Publication Analysis

Top Keywords

handgrip exercise
20
isometric handgrip
16
hemodynamic instability
8
randomized cross-over
8
pilot study
8
exercise
6
handgrip
5
intradialytic isometric
4
hemodynamic
4
exercise hemodynamic
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!