Speckle-Tracking Echocardiography for the Assessment of Atrial Function during Fetal Life.

J Am Soc Echocardiogr

Fetal Cardiology Unit, Department of Congenital Heart Disease, Evelina London Children's Healthcare, Guy's and St. Thomas' NHS Foundation Trust, London, United Kingdom.

Published: November 2020

Introduction: Speckle-tracking echocardiography has become a major tool in the evaluation of heart function. Atrial strain has emerged as an important component in the assessment of cardiac function, but there is a paucity of prenatal data. The aim of this study was to describe our initial experience of measurement of atrial strain in fetuses, with respect to both feasibility and the strain patterns observed.

Methods: Four-chamber Digital Imaging and Communications in Medicine loops were acquired prospectively for deformation imaging. Fifty-three normal fetuses with no morphologic or functional abnormalities were selected for analysis. The three strain components of atrial cycle for both left atrium (LA) and right atrium (RA) were acquired-reservoir (LAres or RAres), conduit, and contraction (LAct or RAct)-and are expressed as a percentage. Ratios of these components were calculated. Simple linear regression was used to analyze how the dependent variables changed according to gestational age and frame rate.

Results: The median gestational age was 30 weeks (range, 23-35), and the frame rate was 74 frames per second (fps; range, 35-121). Left atrial strain was feasible in 48/53 (91%), and right atrial strain in 46/53 (87%) of cases. The onset of LA contraction could be identified on the strain curves in 32 of 48 (67%) cases, and of the RA in 17 of 46 (37%) cases. The values of RAres and RAct were higher compared with those of LAres and LAct (33.9% vs 30.3%, P = .014; and 21.5% vs 16.8%, P = .005), and the contraction:reservoir ratio was also higher for RA (0.63 vs 0.55 for LA, P = .003). Higher values for LAres, LAct, RAres, and RAct were associated with higher frame rate (P = .007, .020, .049, and .012, respectively). The onset of LA contraction was better identified with a higher frame rate (mean 77 vs 59 fps when not seen, P = .007). A higher LA contraction:reservoir ratio was associated with a lower gestational age (P = .042).

Conclusion: Measurement of atrial strain is feasible in the fetal heart. The values are influenced by gestational age and frame rate, so it is necessary to account for these variables. Comparison of left versus right atrial strain values contrasts with those observed postnatally. Atrial function merits further study during fetal life, to aid understanding of maturational changes and disease states.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.echo.2020.06.011DOI Listing

Publication Analysis

Top Keywords

atrial strain
24
gestational age
16
frame rate
16
atrial
9
strain
9
speckle-tracking echocardiography
8
atrial function
8
fetal life
8
age frame
8
strain feasible
8

Similar Publications

Left ventricular non-compaction (LVNC) is a rare primary cardiomyopathy with genetic etiology, resulting from an abnormality of myocardial development during embryogenesis. It carries an elevated risk of left ventricular dysfunction, thromboembolic events and malignant arrhythmias. We report the case of LVNC associated with paroxysmal atrial fibrillation and ankyrin 2 () mutation at the genetic test.

View Article and Find Full Text PDF

In Europe, the prevalence of AF is expected to increase 2.5-fold over the next 50 years with a lifetime risk of 1 in 3-5 individuals after the age of 55 years and a 34% rise in AF-related strokes. The PREFATE project investigates evidence gaps in the early detection of atrial fibrillation in high-risk populations within primary care.

View Article and Find Full Text PDF

: Solid organ transplant recipients (OTR) have been recently involved in exercise prescription programs in order to reduce the high prevalence of cardiovascular diseases. The normal systolic and diastolic cardiac function is fundamental to personalizing the prescription. Diastolic dysfunction can be associated to a higher risk of cardiovascular events and left atrial (LA) strain is an emerging parameter in the evaluation of diastolic compromising, especially in subjects with preserved ejection fraction.

View Article and Find Full Text PDF

Association with Outcome of the Regurgitant-Volume Adjusted Right Ventricular Ejection Fraction in Secondary Tricuspid Regurgitation.

J Am Soc Echocardiogr

January 2025

Department of Medicine and Surgery, University of Milano-Bicocca, Milan, Italy; Department of Cardiology, Istituto Auxologico Italiano, IRCCS, Milan, Italy.

Background: In patients with secondary tricuspid regurgitation (STR), right ventricular ejection fraction (RVEF) may not accurately reflect the actual RV systolic performance since a considerable amount of the RV stroke volume (SV) is regurgitated back into the right atrium. To overcome this limitation, we explored the association with the outcome of the effective RVEF (eRVEF), which accounts for the tricuspid regurgitant volume (RegVol).

Methods: 513 patients with STR (mean age 75±13 years, 39% atrial STR, 58% severe) underwent complete two-, three-dimensional, and Doppler echocardiography.

View Article and Find Full Text PDF

Background: In developing countries, rheumatic mitral valve stenosis (MS) is still a problem and its progression leads to left atrial (LA) damage. Due to the complexity of the LA geometry, currently used techniques like antero-posterior dimension (LAD) and 2D echo derived LA volume (LAV) have several limitations that are corrected by 3D derived LA volumes in addition to functional evaluation.

Purpose: To assess the LA functions using 2D speckle tracking echocardiography and 3D transthoracic echocardiography in patients with clinically significant MS in comparison to normal healthy subjects.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!