A High-Strength Strain Sensor Based on a Reshaped Micro-Air-Cavity.

Sensors (Basel)

Guangdong and Hong Kong Joint Research Centre for Optical Fibre Sensors, College of Physics and Optoelectronic Engineering, Shenzhen University, Shenzhen 518060, China.

Published: August 2020

We demonstrate a high-strength strain sensor based on a micro-air-cavity reshaped through repeating arc discharge. The strain sensor has a micro-scale cavity, approximate plane reflection, and large wall thickness, contributing to a broad free spectrum range ~36 nm at 1555 nm, high fringe contrast ~38 dB, and super-high mechanical robustness, respectively. A sensitivity of ~2.39 pm/με and a large measurement range of 0 to 9800 με are achieved for this strain sensor. The strain sensor has a high strength, e.g., the tensile strain applied the sensor is up to 10,000 με until the tested the single-mode fiber is broken into two sections. In addition, it exhibited low thermal sensitivity of less than 1.0 pm/°C reducing the cross-sensitivity between tensile strain and temperature.