Sensory information is processed in the visual cortex in distinct streams of different anatomical and functional properties. A comparable organizational principle has also been proposed to underlie auditory processing. This raises the question of whether a similar principle characterize the somatosensory domain. One property of a cortical stream is a hierarchical organization of the neuronal response properties along an anatomically distinct pathway. Indeed, several hierarchies between specific somatosensory cortical regions have been identified, primarily using electrophysiology, in non-human primates. However, it has been unclear how these local hierarchies are organized throughout the cortex. Here we used phase-encoded bilateral full-body light touch stimulation in healthy humans under functional MRI to study the large-scale organization of hierarchies in the somatosensory domain. We quantified two measures of hierarchy of BOLD responses, selectivity and laterality. We measured how selectivity and laterality change as we move away from the central sulcus within four gross anatomically-distinct regions. We found that both selectivity and laterality decrease in three directions: parietal, posteriorly along the parietal lobe, frontal, anteriorly along the frontal lobe and medial, inferiorly-anteriorly along the medial wall. The decline of selectivity and laterality along these directions provides evidence for hierarchical gradients. In view of the anatomical segregation of these three directions, the multiplicity of body representations in each region and the hierarchical gradients in our findings, we propose that as in the visual and auditory domains, these directions are streams of somatosensory information processing.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.neuroimage.2020.117257 | DOI Listing |
Anal Chem
January 2025
Center of Clinical Laboratory Medicine, Zhongda Hospital, Medical School of Southeast University, Nanjing 210009, Jiangsu, China.
The incidence of cervical cancer continues to rise in underdeveloped regions due to low human papillomavirus (HPV) vaccination rates and inadequate screening systems. To achieve convenient, rapid, and accurate detection of HPV, we developed a three-wire lateral flow strip assay system based on dual-OR logic gates for rapid and simultaneous detection of HPV subtypes 16 and 18 in a single test. The system combines three-branch-catalytic hairpin assembly (TCHA)-mediated signal amplification with simple OR logic gate-based signal output to improve detection rates while enabling HPV 16/18 subtype identification.
View Article and Find Full Text PDFTraffic Inj Prev
January 2025
Department of Civil Engineering, Indian Institute of Technology, Indore, India.
Objective: The study aims to develop continuous trajectory profiles along curves with minimal error. It also focuses on formulating a percentage trajectory transection rate model as a function of geometric parameters (e.g.
View Article and Find Full Text PDFJ Pediatr Orthop
January 2025
Department of Pediatric Orthopaedic Surgery, Robert Debré University Hospital, Assistance Publique des Hôpitaux de Paris (AP-HP).
Background: Lower instrumented vertebra (LIV) selection for adolescent idiopathic scoliosis (AIS) with structural lumbar curves (Lenke 3, 5, and 6) remains debated. The iliolumbar angle (ILA) measurement is useful for assessing the lumbosacral junction flexibility. If it is nonreducible, surgeons need to make a difficult choice between a potential "imperfect" L4, associated with a residual lumbosacral curve, or a more distal fusion performed later in life due to poorer functional outcomes.
View Article and Find Full Text PDFOptical glass selection is an important research object in optical design, which is an important way to aberration correction. However, these methods to our knowledge either do not correct aberration well or consume too much time. To efficiently solve the apochromatic problems in optical design, this paper presents what we believe to be a novel automatic optimization method for discontinuous optical glass based on auto glass selection (AGS).
View Article and Find Full Text PDFComput Biol Med
January 2025
Khalifa University, Abu Dhabi, United Arab Emirates. Electronic address:
Musculoskeletal modeling based on inverse dynamics provides a cost-effective non-invasive means for calculating intersegmental joint reaction forces and moments, solely relying on kinematic data, easily obtained from smart wearables. On the other hand, the accuracy and precision of such models strongly hinge upon the selected scaling methodology tailored to subject-specific data. This study investigates the impact of upper body mass distribution on internal and external kinetics computed using a comprehensive musculoskeletal model during level walking in both normal weight and obese individuals.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!