Incidence and predisposing factors of anterior chamber gas bubbles during femtosecond laser flap creation.

Int J Ophthalmol

Chiang Mai University LASIK Center, Center of Medical Excellence; Department of Ophthalmology, Faculty of Medicine, Chiang Mai University, Chiang Mai 50200, Thailand.

Published: August 2020

Aim: To investigate the incidence and the predisposing factors of anterior chamber (AC) gas bubbles during femtosecond laser (FS) flap creation for laser keratomileusis (LASIK).

Methods: All patients who underwent FS-LASIK surgery at CMU LASIK Center between January 2013 and May 2016 were retrospective reviewed. Preoperative and intraoperative data including keratometry, white-to-white (WTW) corneal diameter, flap parameters (diameter, thickness, hinge position, and tunnel length) and pulse energy were reviewed and compared between incident group and control group. To determine the risk factors, univariate and multivariate conditional logistic regression were used; the eye was unit of analysis.

Results: The incidence of AC gas bubbles was 1.6% (22 out of 1378 eyes). The median WTW in the AC bubbles group was 11.5 mm (range 11.1-12.1), which was significantly different from the control group (11.7 mm, range 10.5-12.8, =0.021). The result of the median WTW minus the flap diameter in the AC bubbles group was 2.5 mm (range 2.1-3.2), which was statistically different to the control group (2.7 mm, range 1.5-3.8, =0.008). The logistic regression analysis showed that the result of the WTW minus the flap diameter in the AC bubbles group had an adjusted odds ratio of 0.204 (95%CI; 0.056-0.747, =0.016).

Conclusion: Development of AC gas bubbles during FS flap creation is not an uncommon event in Asian eyes which typically have a small WTW. The flap diameter when adjusted relatively to the WTW is a predisposing factor to the possibility of AC gas bubbles occurrence.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7387908PMC
http://dx.doi.org/10.18240/ijo.2020.08.22DOI Listing

Publication Analysis

Top Keywords

gas bubbles
20
flap creation
12
control group
12
bubbles group
12
flap diameter
12
incidence predisposing
8
predisposing factors
8
factors anterior
8
anterior chamber
8
chamber gas
8

Similar Publications

Compounds featuring bonds between mercury and transition metals are of interest for their intriguing/ambiguous bonding and scarcely explored reactivities. We report herein the synthesis and reactivities of the new compound [(POCOP)Ni]2Hg, [Ni2Hg], featuring a trinuclear Ni-Hg-Ni core (POCOP = κP,κC,κP´-2,6-(i-Pr2PO)2C6H3). [Ni2Hg] reacts with CO2 to give the carbonate-bridged complex [Ni2CO3].

View Article and Find Full Text PDF

Microfluidic Monodispersed Microbubble Generation for Production of Cavitation Nuclei.

Micromachines (Basel)

December 2024

Department of Mechanical Engineering, The University of Memphis, Memphis, TN 38152, USA.

Microbubbles, acting as cavitation nuclei, undergo cycles of expansion, contraction, and collapse. This collapse generates shockwaves, alters local shear forces, and increases local temperature. Cavitation causes severe changes in pressure and temperature, resulting in surface erosion.

View Article and Find Full Text PDF

In coronary artery bypass grafting (CABG) on pump, achieving optimal visualization is critical for surgical precision and safety. The use of blowers to clear the CABG anastomosis poses risks, including the formation of micro-embolic gas bubbles, which can be insidious and increase the risk of cerebral or myocardial complications. This retrospective study compares the effectiveness of the use of irrigation mist and CO versus a direct CO blower without irrigation in terms of visualization, postoperative fibrillation, and micro-embolic gas activity.

View Article and Find Full Text PDF

Removal of Subretinal Gas After Pneumatic Retinopexy Under Air Using External Manipulation.

Retin Cases Brief Rep

January 2025

The Retina Service of Wills Eye Hospital, Wills Eye Physicians-Mid Atlantic Retina, Thomas Jefferson University, Philadelphia, PA.

Purpose: To illustrate a technique for the removal of subretinal gas via pars plana vitrectomy (PPV) with air-fluid exchange and simultaneous manipulation with scleral depression.

Methods: PPV to remove subretinal gas causing persistent macula-off retinal detachment was performed in one eye, and the results were evaluated in this case report. Ports were carefully placed to avoid puncturing the retina, which was significantly displaced anteriorly past the ora serrata due to the buoyancy of the subretinal gas with the patient in a supine position.

View Article and Find Full Text PDF

An in-situ study in the Xijiang River basin revealed adverse effects of total dissolved gas supersaturation on fish.

Ecotoxicol Environ Saf

January 2025

State Key Laboratory of Hydraulics and Mountain River Engineering, Sichuan University, Chengdu 610065, China.

High dam discharge can lead to total dissolved gas (TDG) supersaturation in downstream rivers, causing fish to suffer from bubble trauma and even mortality. Focusing on the Datengxia hydropower station in the Xijiang River basin, we conducted in-situ experiments to explore the tolerance patterns of economic fish species, including Ctenopharyngodon idella, Hypophthalmichthys molitrix, and Cirrhinus molitorella, under the influence of TDG supersaturation at different compensation depths. Moreover, the development and recovery patterns of bubble trauma and the swimming ability of fish exposed to TDG supersaturated water were investigated.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!