A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Performance of normal-hearing listeners on the Repeat-Recall test in different noise configurations. | LitMetric

Objective: This study measured the performance of normal-hearing listeners on the Repeat-Recall Test (RRT) in two noise types (2-talker babble [2TBN] and continuous speech-shaped noise [SSN]) by two noise azimuths (0° and 180°) configurations at signal-to-noise ratios (SNRs) of 0, 5, 10, and 15 dB and quiet.

Design: Within-subject repeated measures.

Study Sample: Twenty-one listeners with normal hearing who also passed cognitive screening were tested in the sound-field with the speech stimulus presented from 0° at 75 dB SPL in 4 noise configurations. The order of SNRs, noise configurations, and RRT topic conditions was counterbalanced across listeners.

Results: Analysis revealed that repeat scores were significantly better for 2TBN, for noise at 180°, and for high context (HC) sentences. Recall performance was significantly better for SSN and HC sentences. Listening effort ratings were higher for SSN and for noise front condition at SNR ≤ 10 dB. The 2TBN noise was tolerated longer than SSN. Performance on all measures improved with SNRs.

Conclusions: These data showed performance differences among noise configurations and provided a preliminary basis for comparison with hearing-impaired listeners' performance on the RRT.

Download full-text PDF

Source
http://dx.doi.org/10.1080/14992027.2020.1807626DOI Listing

Publication Analysis

Top Keywords

noise configurations
16
noise
10
performance normal-hearing
8
normal-hearing listeners
8
listeners repeat-recall
8
repeat-recall test
8
2tbn noise
8
performance
6
configurations
5
test noise
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!