X-ray tube with artificial neural network model as a promising alternative for radioisotope source in radiation based two phase flowmeters.

Appl Radiat Isot

Institute of Fundamental and Applied Sciences, Duy Tan University, Ho Chi Minh City, Viet Nam; Faculty of Electrical, Electronic Engineering, Duy Tan University, Da Nang, 550000, Viet Nam; Nuclear Science and Technology Research Institute, Tehran, Iran.

Published: October 2020

In this paper, X-ray tube is introduced as a potential alternative for radioisotope sources used in radiation based liquid-gas two-phase flowmeters. X-ray tubes have lots of advantages over the radioisotope sources such as having an adjustable emitting photon's energy, being safer from point of view of radiation health physics during the transportation of the source, having ability to generate a high flux photon beam, and etc. The proposed radiation based system in this study composes an X-ray tube with a tube voltage of 150 kV and a 2.5 mm aluminum filter as the radiation source and one sodium iodide crystal as the photon detector. A pipe was positioned between the X-ray tube and the detector. Two main flow regimes of annular and stratified with different void fractions were modelled inside the pipe. Artificial neural network model of multi-layer perceptron (MLP) was also used in this study for analyzing the obtained data. The output spectrum of sodium iodide detector with 150 samples was applied as the input of multi-layer perceptron network and void fraction was considered as its output. The root mean squared error of proposed measuring system was 4.13 which shows the X-ray tube can be implemented as a promising alternative for radioisotope in radiation based two phase flow meters.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.apradiso.2020.109255DOI Listing

Publication Analysis

Top Keywords

x-ray tube
20
radiation based
16
alternative radioisotope
12
artificial neural
8
neural network
8
network model
8
promising alternative
8
based phase
8
radioisotope sources
8
sodium iodide
8

Similar Publications

Damage of fallopian tube, endometriosis, fibroid uterus, adenomysis and polycystic ovary syndrome are the major pelvic pathology that causes subfertility. Although there are many diagnostic tests available, the clinical presentation of each patient can usually be linked to specific and efficient testing strategies. Transvaginal sonographic (TVS) imaging is an effective, easy to use, safe and readily available noninvasive means to evaluate fertility potential.

View Article and Find Full Text PDF

This study aims to explore the feasibility of applying the "Three-Low" technique (low injection rate, low iodine contrast volume, low radiation dose) in coronary CT angiography (CCTA). We prospectively collected data from 90 patients who underwent CCTA at our hospital between 2021 and 2024. The patients were randomly assigned to either the experimental group (n = 45) or the control group (n = 45).

View Article and Find Full Text PDF

Respiratory interventions including noninvasive ventilation, continuous positive airway pressure and high-flow nasal oxygen generated infectious aerosols may increase risk of airborne disease (SARS-CoV-2, influenza virus) transmission to healthcare workers. We developed and tested a prototype portable UV-C device to sterilize high flows of viral-contaminated air from a simulated patient source at airflow rates of up to 100 l/m. Our device consisted of a central quartz tube surrounded 6 high-output UV-C lamps, within a larger cylinder allowing recirculation past the UV-C lamps a second time before exiting the device.

View Article and Find Full Text PDF

Background: Ectopic pregnancy, occurring outside the uterine cavity, poses a significant health risk, with Fallopian tube involvement being predominant. Recurrent ectopic pregnancy, particularly in the ipsilateral remnant of a previously removed tube, is a rare and poorly understood phenomenon. Here, we present a case of recurrent ectopic pregnancy occurring in the distal remnant of the right fallopian tube following ipsilateral incomplete salpingectomy in a 22-year-old woman.

View Article and Find Full Text PDF

Real-time computed tomography fluoroscopy-guided dye marking prior to robotic pulmonary resection.

J Cardiothorac Surg

December 2024

Department of Radiology, Sakai City Medical Center Hospital, Ebaraji-Cho, Nishi-Ku, Sakai-Shi, Osaka, 593-8304, Japan.

Background: The detection of tumor localization is difficult in robotic surgery because surgeons have no sense of touch and rely on visual information. This study aimed to evaluate the efficacy of preoperative CT-guided dye marking of lung nodules prior to robotic surgery.

Methods: Patients undergoing CT-guided dye marking prior to robotic surgery at our hospital between September 2019 and April 2024 were retrospectively analyzed.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!