A method for the theoretical estimation of the MTF of columnar phosphors with a homogeneous part at the end used in X-ray imaging has been developed. This method considers the light transport inside the scintillator through an analytical modelling, the optical photon beams distribution on the scintillator-optical sensor interface, and uses the definition of the PSF and a Gauss fitted LSF to estimate the MTF of an indirect detector. This method was applied to a columnar CsI:Tl scintillator and validated against experimental results found in literature, and a good agreement was observed. It was found that, by increasing the pixel size of the optical detector and the thickness of the scintillator, the MTF decreased as expected. This method may be used in evaluating the performance of the columnar phosphors used in medical imaging, given their physical and geometrical characteristics.Graphical abstract (a) Side view of a part of the scintillator where five crystal columns with homogeneous ends attached to an optical sensor is shown. (b) Propagation of two random optical photon beams emitted from point K with different angles of emission is shown. All the symbols are explained analytically in the text.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s11517-020-02243-4 | DOI Listing |
Angew Chem Int Ed Engl
February 2021
Building Blocks for FUture Electronics Laboratory, UMI 2002, CNRS-Sorbonne Université-Yonsei University, Yonsei University, 50 Yonsei-ro, Seodaemun-gu, Seoul, 03722, South Korea.
Long-lived room temperature phosphorescence from organic molecular crystals attracts great attention. Persistent luminescence depends on the electronic properties of the molecular components, mainly π-conjugated donor-acceptor (D-A) chromophores, and their molecular packing. Here, a strategy is developed by designing two isomeric molecular phosphors incorporating and combining a bridge for σ-conjugation between the D and A units and a structure-directing unit for H-bond-directed supramolecular self-assembly.
View Article and Find Full Text PDFMed Biol Eng Comput
October 2020
Department of Medical Physics, School of Medicine, University of Patras, 26500, Patras, Greece.
A method for the theoretical estimation of the MTF of columnar phosphors with a homogeneous part at the end used in X-ray imaging has been developed. This method considers the light transport inside the scintillator through an analytical modelling, the optical photon beams distribution on the scintillator-optical sensor interface, and uses the definition of the PSF and a Gauss fitted LSF to estimate the MTF of an indirect detector. This method was applied to a columnar CsI:Tl scintillator and validated against experimental results found in literature, and a good agreement was observed.
View Article and Find Full Text PDFInorg Chem
October 2018
Instituto de Ciencia de Materiales de Aragón (ICMA), Departamento de Química Orgánica, Facultad de Ciencias , Universidad de Zaragoza - CSIC , 50009 Zaragoza , Spain.
Three cyclic trinuclear pyrazolate complexes with Au(I), Ag(I), or Cu(I) have been studied. These complexes have interesting and distinct optical and thermal properties depending on the metal, namely, liquid crystalline behavior, red or deep-red phosphorescence at room temperature, thermoluminochromism, and response to silver ions. The selected ligand, 4-hexyl-3,5-dimethylpyrazolate, maximizes the effect that the nature of the metals has on the properties of the complexes, thus allowing the intermolecular metallophilic interactions to be responsible for the optical properties.
View Article and Find Full Text PDFPhys Med
March 2017
Department of Medical Physics, School of Medicine, University of Patras, Patras 26500, Greece. Electronic address:
Purpose: An analytical model has been developed for the light propagation in columnar phosphors, based on the optical photon propagation physical and geometrical principles.
Methods: This model accounts for the multiple reflections on the sides of the crystal column, as well as for the infinite forward and backward reflections of the propagated optical photon beams created in the crystal bulk. Additionally it considers the lateral propagated optical photon beams after multiple refractions from the neighbor columns and the optical photon attenuation inside the scintillator.
Med Phys
June 2016
R&D Center, DRTECH Co., Gyeonggi-do 13558, South Korea.
Purpose: The fixed pattern noise in radiography image detectors is caused by various sources. Multiple readout circuits with gate drivers and charge amplifiers are used to efficiently acquire the pixel voltage signals. However, the multiple circuits are not identical and thus yield nonuniform system gains.