Combined volar and dorsal plating vs. volar plating of distal radius fractures. A single-center study of 105 cases.

Hand Surg Rehabil

Department of Hand Surgery, Faculty of Medicine and Health, Örebro University, Södra Grev Rosengatan, 70185 Örebro, Sweden. Electronic address:

Published: December 2020

Despite recent advances in the surgical management of distal radius fractures (DRFs), the optimal treatment remains controversial as different fixation methods often have similar clinical functional and radiographic outcomes. The objective of this study was to assess the differences in outcomes 1 year postoperatively between volar plating and combined plating for DRFs. In a retrospective cohort study, we evaluated 105 consecutive patients operated with either a volar locking plate or combined dorsal and volar plating. The primary outcome was wrist range of motion (ROM). Secondary outcome measures included hand grip strength, visual analog scale (VAS) pain scores, radiographic examination and patient-related outcome measures. Patients treated with combined plating had significantly inferior wrist flexion, extension and ulnar deviation. The radiographic Batra score 1 year postoperatively was similar for both groups. The PRWE (patient-rated wrist evaluation) score was 16 for the volar plating group and 14 for the combined plating group. The QuickDASH (Quick disabilities of the arm, shoulder and hand) score was 9 for the volar plating group and 16 for the combined plating group. VAS pain scores were 0 at rest and 2 during activity for both groups. Grip strength was similar between the two groups. Hardware removal was done in 18/78 patients for the combined plating group and 1/27 for the volar plate group. Two patients operated with combined plating had tendon ruptures. Our findings indicate that both methods can yield satisfactory clinical and radiographic outcomes. However, combined plating resulted in inferior wrist ROM and substantially higher frequency of hardware removal. The potential advantages of combined plating in stabilizing a comminuted DRF must be balanced by the potential drawbacks such as inferior wrist ROM and higher frequency of hardware removal.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.hansur.2020.07.006DOI Listing

Publication Analysis

Top Keywords

combined plating
32
volar plating
20
plating group
20
plating
14
inferior wrist
12
hardware removal
12
combined
10
distal radius
8
radius fractures
8
radiographic outcomes
8

Similar Publications

Along with the rapid development of the digital economy and artificial intelligence, heat sinks available for immersion phase-change liquid cooling (IPCLC) of chips are facing huge challenges. Here, we design a high-performance IPCLC heat sink based on a copper microgroove/nanocone (MGNC) composite structure. Maximal heat fluxes () of the MGNC structure, microgroove structure, and flat copper reach 112.

View Article and Find Full Text PDF

Automated High-Throughput Affinity Capture-Mass Spectrometry Platform with Data-Independent Acquisition.

J Proteome Res

January 2025

Discovery Research, AbbVie, Inc., 1 North Waukegan Rd., North Chicago, Illinois 60064, United States.

Affinity capture (AC) combined with mass spectrometry (MS)-based proteomics is highly utilized throughout the drug discovery pipeline to determine small-molecule target selectivity and engagement. However, the tedious sample preparation steps and time-consuming MS acquisition process have limited its use in a high-throughput format. Here, we report an automated workflow employing biotinylated probes and streptavidin magnetic beads for small-molecule target enrichment in the 96-well plate format, ending with direct sampling from EvoSep Solid Phase Extraction tips for liquid chromatography (LC)-tandem mass spectrometry (MS/MS) analysis.

View Article and Find Full Text PDF

Background: Liver fibrosis is a serious global health issue, but current treatment options are limited due to a lack of approved therapies capable of preventing or reversing established fibrosis.

Aim: This study investigated the antifibrotic effects of a synthetic peptide derived from α-lactalbumin in a mouse model of thioacetamide (TAA)-induced liver fibrosis.

Methods: analyses were conducted to assess the physicochemical properties, pharmacophore features, and docking interactions of the peptide.

View Article and Find Full Text PDF

Therapeutic effect of titanium locking plate combined with suture anchor repair in proximal humeral fractures.

Pak J Med Sci

January 2025

Zhenfeng Huang Department of Orthopedic Trauma, Wuhan Fourth Hospital, Wuhan, Hubei Province 430000, P.R. China.

Objective: To explore the therapeutic effect of titanium locking plate combined with suture anchor (SA) repair in the treatment of proximal humeral fractures (PHF).

Methods: This retrospective study was conducted by analyzing the clinical data of 113 patients with PHF admitted to Wuhan Fourth Hospital from March 2021 to October 2023. Among them, 55 patients underwent open reduction and internal fixation (OR/IF) using titanium locking plate (OR/IF group), and 58 patients underwent surgery with titanium locking plate combined with SA (SA group).

View Article and Find Full Text PDF

Purpose: To compare the efficacy and safety of skip titanium plates combined with adjacent spinous process suture suspension versus continuous titanium plate fixation in cervical laminoplasty.

Methods: A retrospective analysis of 125 patients (62 men, 63 women, average age 60.9 ± 10.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!